A six-cylinder rack containing an argon / hydrogen mixture is dropped from a truck on a national highway, causing a gas leak. A security perimeter was set up. The services of the equipment took care…

The event occurred in a research laboratory on renewable energies and decarbonisation. The Lab Manager had swapped a hydrogen cylinder, together with the delivery personnel. They secured the…

During the pre-launch checkout, a check valve failed in the "open" position and an accidental venting of liquid hydrogen occurred. The event caused an unscheduled check and replacement…

During the development test of a booster, a 3000 psig (ca. 205 bar) relief valve actuated at the normal line pressure releasing gaseous hydrogen, which ignited, resulting in an explosion which…

This incident consisted in the accidental release of a CGH2 tube trailer after that it had rolled sideward on the ground. A hydrogen delivery company driver arrived at the customer site to…

A truck was traveling on a highway carrying three hydrogen pallets. When trying to pass a vehicle ahead, the driver moved too far to the right, causing the wheels to hitting a snow-covered…

During the start-up of a propylene hydrogenation reactor, very high temperatures were generated in the catalyst bed. At the time, propylene and hydrogen were being fed to the reactor which contained…

This event summarises 3 very similar cases of leaks at dispenser hoses during refuelling, occurred at the same hydrogen refuelling station in the period January - April 2017. The leaks triggered…

A leak developed on a CGH2 tube trailer on the pigtail of one of the tube. The pigtail was cracked, possibly due to vibration. This trailer was tested the day before this incident and was found to…

A LH2 trailer/truck were travelling on a highway when they noticed vapour coming from the trailer cabinet. They exited the highway, parked and opened the trailer cabinet. They found that a nut had…

The event occurred while re-starting the ammonia production unit after a technical stop, a synthesis gas (50% hydrogen, 17% ammonia, methane and nitrogen) leak ignited on a flange located just after…

During loading of a LH2 storage tank, the vent valve on the tank was opened and then ignition occurred near the instant that the valve was fully open. A light pressure wave was produced. The cloud…

During transfer operations of a liquid hydrogen from a tanker, a release of hydrogen occurred, which resulted in the detection of hydrogen in an adjacent building. The normal procedure could not…