Release of LH2 due valve failure
During the pre-launch checkout, a check valve failed in the "open" position and an accidental venting of liquid hydrogen occurred. The event caused an unscheduled check and replacement of components. [Ordin, NASA (1974)]
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences

An error in an installation drawing occurred in which a wrong part number was called out, resulting in system contamination and valve failure. ROOT CAUSE was an installation error enabled by a design error. It is however unclear the reason for the mentioned contamination.