Skip to main content

HIAD Event Initiating System: Non-Hydrogen System Initiating Event


During the polymerization of ethylene in a 750 litres pressurized reactor, an exothermic runaway decomposition occurred and ethylene and its decomposition products were released through the two…
A deflagration occurred inside the tank at the start of grinding operations. The tank had contained sulphuric acid. All preparatory procedures had been properly carried out: neutralisation of…
A wash machine was being used to clean aluminium trays with burnt on product. The auto wash in normal situations cleaned steel trays, and not aluminium. The cleaning fluid contained sodium hydroxide…
The explosion occurred at the second floor of university building, where a postdoc researcher was conducting a chemical experiment using hydrogen gas in the laboratory. First a chemical fire started…
A pinhole leak in the discharge hose of a portable tank containing sodium hydride reacted with water, and released hydrogen that ignited and exploded at a waste management plant.
An explosion occurred around noon while conducting hot work (with a disc saw) on a 320-m³ fixed-roof tank at a pharmaceutical plant employing 240 personnel. The tank belongs to a waste treatment unit…
This incident occurred at a waste water tank of an unspecified chemical plant. An explosive atmosphere formed inside the wastewater tank due to the accidental production of hydrogen. This occurred…

This incident took place at a plant specialised in production of sodium, lithium, and chlorine. A hydrogen explosion occurred during the hydrolysis of sodium residues in a dedicated workshop.…

The explosion was caused by the ignition of hydrogen during reaction with sodium metal. The Chemistry Department routinely dried solvents using metallic sodium. This leaves an excess of sodium metal,…
An explosion occurred whole two employees inside a facility were working with aluminium paste. Crews believed the blast was caused by hydrogen that had built up in the plant.
Hydrogen was accidentally produced inside the sealed container containing a used battery. The gas, along 6 days deformed the container. Firefighters equipped with breathing apparatus opened the…
The explosion occurred in a copper electroplating plant test furnace when starting the operation of copper plating. A tinned copper pipe had been placed inside another copper pipe and lined with…
In the acid treatment room of a Seveso low-threshold hazardous waste treatment centre, an explosion occurred on a 250 m³ concrete tank containing acid sludge being neutralized. The explosion occurred…
The explosion occurred in an incinerator for non-industrial wastes, during inspection and repair works. These were due to a large quantity of aluminium which produced a solid lump of ash. The…
Works at the power grid of a hydrogen production unit is at the origin of the sequence of the following events: 1. Fusion of a safe fuse triggering the closure of a valve on the manifold of a pistons…
Five barrels of aluminium dust that had been removed from an outdoor dust collector were sealed and stored in the plant adjacent to electrical panels. One of them had somehow been contaminated with…
At an agrochemical plant, an explosion occurred near a drained hydrofluoric acid tank, when 4 employees were welding on adjacent pipelines. An investigation was launched to determine this accident’s…
The Microbiological Anaerobic Chamber of approximately 2 m3 capacity was containing an explosive mixture of hydrogen and air. A fire followed the explosion, but was rapidly extinguished by staff…
In a graphite purification workshop, the cooling circuit of an electric furnace leaks, the water decomposes in contact with materials heated to a temperature of 1,800°C; the gas mixture (hydrogen,…
Explosion in a chemical manufacturing plant for the pharmaceutical and cosmetics industries, classified as Seveso high level,The explosion occurred in the hydrogenation reactor, when opening two…