Skip to main content

Explosion in the furnace of a graphite manufacturing plant (914)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion in the furnace of a graphite manufacturing plant

In a graphite purification workshop, the cooling circuit of an electric furnace leaks, the water decomposes in contact with materials heated to a temperature of 1,800°C; the gas mixture (hydrogen, air. . . ) explodes. The carbon contained in the furnace is dispersed and ignites.
Event Date
September 17, 1995
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
INITIATING CAUSE was the leaking of water into the high temperature reactor, which brought to water thermolysis. Nothing is known on the reason for the leak.
Facility Information
Application Type
Application
graphite production
Specific Application Supply Chain Stage
Components Involved
graphite purification reactor
Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Post-event Summary

The furnace and the roof covering it were destroyed.

Event Nature
Emergency Action
The local residents alert the fire brigade. The fire is extinguished with powder (including carbon).
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Description of the event in the French database ARIAhttps://www. aria. developpement-durable. gouv. fr/accident/10466/(accessed September 2020)