A truck carrying cylinders was travelling on a highway when its front tyre burst. It rolled over in a farm and the gas started leaking from the cylinders. The driver called the emergency service.…

A trailer-truck transporting hydrogen gas cylinders was involved in a collision on a highway, experienced a partial roll-over and cough fire. The online news do not report the origin of the fire.…

A truck driver carrying compressed gas cylinders loaded on pallets stopped on the emergency stop lane of a highway after a tyre burst. The gases transported were: 120 m³ of oxygen, 24 acetylene…

A trailer-tractor carrying a liquid hydrogen took fire on a highway. The fire was due to a malfunction of the diesel engine fuel injection system. The fire engulfed the whole cabin of the tractor.…

The boat was performing a drive test when one of the 280 lead gel batteries exploded and took fire. The local fire brigade was able to extinguish the fire but the above deck section of the boat was…
A compressed hydrogen trailer released accidentally hydrogen which ignited producing a hissing 60 jet flame. It triggered the evacuation of a one-mile stretch. It was estimated that the tanker burned…

A tube ruptured in the charge heater ('fired heater') of a desulphurisation reactor due to a blockage caused by accelerated coking. Flames spread over an area of some 100 feet outward…

A hydrogen and batteries driven aircraft was forced to land after a flight incident. According to the aircraft company the aircraft was forced to an emergency landing, but landed normally on its…
A fire broke out affecting the heavy fuel purification plant of the refinery. The incident could have originated by the failure of one of the following plant components: - pipes leading to the…
In a plastics production plant, a pallet containing 7 cylinders of nitrogen and 1 cylinder of hydrogen fell from a truck traveling in a logistics zone. The driver stopped the vehicle, cut off the…
Three workers were asphyxiated when argon and hydrogen gas leaked from pipes they were installing on an aromatics plant being built on a cracking complex.

A hydrogen explosion occurred in a 5-tonne stainless steel pressure vessel, while two electro-polisher workers where electropolishing internal surfaces. The cause is believed to be the build-up…

A fire, fuelled by a mixture of gasoline and hydrogen, occurred on a heat exchanger located at 15 m height in a gasoline processing unit of a refinery. The operator triggered the emergency plan. Site…
In a petrochemical plant, a gas mixture at 270 bar made of 75% hydrogen (H2) and 25% methane (CH4) leaked through the bottom valve of a dryer of a resin production unit. After detection of the leak,…
The event occurred in the continuous casting of hot metallic melt of the plant. Cooling water leaked through a crack in the cooling water inlet pipe of a secondary cooling line and directly into the…
The explosion occurred when a spark from welding equipment ignited flammable vapours from a 415,000-gallon (ca. 1. 5 million of litres) sulphuric acid storage tank at the refinery. The investigation…
The incident occurred in a building containing the residues of the production of sodium, lithium and chlorine. The alarm was given by an employee who heard detonations coming from the building. A few…
The explosion occurred while maintenance personnel were grinding a high-pressure injection (HPI) pipe, which had been recently cut at approximately 18 inches from the nozzle connecting the HPI pipe…
In a chemical plant (SEVESO), corrosion on the water side of a cooling exchanger caused water to enter the sulphuric acid and attack the steel in the tank. This reaction produced hydrogen that…
The sodium chlorate production unit had restarted after a maintenance shutdown phase. The mercury cells had been under nitrogen flushing since the beginning of the shutdown to avoid the presence of…