During transfer of LH2 from a 200,000 gallon (760 m3) storage vessel to a road trailer, loss of vacuum was detected due to a crack in the outer vessel. The crack was located below an elbow of the…
A liquid hydrogen tanker was travelling on a highway, when it overturned. The product remained secure within the trailer and there was release to atmosphere during the accident. During the clean…
A LH2 hydrogen went off road and overturned. There was no spillage. All regulatory agencies were notified and the road was closed for an extended period of time.
A liquid hydrogen tanker (with a water capacity of 2000 l) was passing a highway interchange, when the safety valve of the tank activated, releasing hydrogen gas. The drivers stopped first on the…
This near miss affected a testing installation for liquid hydrogen. A leak was located on a valve installed on a purge line connected with a LH2 storage tank. This shut-off valve served to…
A rupture disc opened on a 76 m3 (20,000-gallon) liquid hydrogen tank, causing the vent stack to release cold gaseous hydrogen. The gas ignited causing a fire on the vent stack's outlet.…
According to local news, a "hydrogen tanker truck hauling was on fire" at a travel centre on a highway. The videos show, however, simply a flame from what probably is the pressure relief…
While on a highway, the driver of a liquid hydrogen tanker was notified that vapour was coming out of the back of the trailer. The driver pulled into a safe haven to investigate. After opening the…
During the transit of 10 000 gallons (ca. 39000 l) LH2 transport vessel, the venting rate became extremely high . The annular vacuum appeared to be lost showing large patches of condensed water at…
The drivers failed to lower the internal pressure of a liquid hydrogen tanker before leaving plant. Therefore they had to stop en route and vent 4000 scf of hydrogen. [Zalosh and Short, 1978]
A liquid hydrogen tanker was returning empty to the base, when a pressure build-up forced the drivers to perform a manual venting. [Zalosh and Short, 1978]
The drivers failed to stabilise the tank pressure after having delivered the liquid hydrogen. Therefore they had to stop and perform a manual vent on journey back to the base. [Zalosh and Short,…
Before loading it with liquid hydrogen, the cyrogenic tank had been purged with nitrogen for maintenance work. After the loading, the drivers failed to stabilise the internal pressure of the tank,…
The pressure building valve opened due to vibration from the road, causing the build-up of the internal pressure. The drivers performed a hydrogen venting and re-sealed the valve. [Zalosh and…
A pressure build-up in the tank of a liquid hyrogen tanker caused the drivers to vent 6000 cu ft of hydrogen to reduce the pressure. [Zalosh and Short, 1978]