An empty liquid Hydrogen tanker was returning to the base terminal from a delivery at a space centre. At the departure, the internal vessel pressure was 8 psig. At the first safety check, the…
A liquid hydrogen tanker was loaded at the home base and dispatched to a customer (approximately 790 km). The internal vessel pressure after filling was 8 psig (1. 4 bara). During transit, the…
A liquid hydrogen tanker was travelling from the home terminal to delivery to a customer. After approximately 7 hours and 400 miles, the drivers noticed hydrogen venting from the vent stack. They…
When travelling to a customer, a liquid hydrogen tanker experienced a slight tank pressure increase due to an improper cooling down. The driver was carefully monitoring the pressure and when he…
A liquid hydrogen tanker was returning almost empty to the base terminal. The drivers noted a pressure rise in the tanker stopped at a remote area of a rest area and performed a controlled venting…
The second stage of the Saturn V (S-II-T) was under full-duration static test, when one fire near LH2 valves of the LH2 tank and another in the engine area caused the automatic termination of the…
A liquid hydrogen tanker had been slightly overloaded. This forced the drivers to performed a manually venting releasing 5000 cu. ft. of hydrogen. [Zalosh and Short, 1978]
During a leak check of a flash point material testing chamber, the chamber was inadvertently over-pressurised with GH2. The glass port in the door burst, causing damage to the chamber and to the…
A fire broke out at a pipe of the hydrogen production unit, belonging to the steam methane reformer part of the fluidised catalytic cracking (FCC) plant. The fire occurred when personnel of a…
A manufacturer of fuel cells and hydrogen vehicles issued a recall for 35 of its vehicles, due to a manufacturing defect in the Thermal Pressure Relief Device (TRPD). The defect may cause the…
While a H2 sample was being prepared for an analysis, one of two cryogenic sample bottle disks ruptured and the gas ignited. [Ordin, NASA (1974)]
A CGH2 tube trailer was transferring hydrogen to a customer cylinder skid. The pressure relief on the customer system opened, the escaping hydrogen ignited and burned for approximately 10-15…