Overpressure damage in a testing facility
During a leak check of a flash point material testing chamber, the chamber was inadvertently over-pressurised with GH2. The glass port in the door burst, causing damage to the chamber and to the facility. [Ordin, NASA (1974)]
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The ROOT CAUSE was design deficiencies in the test chamber and installation. The pressure source was 150 psig (11 bara) and the chamber working pressure was 16. 5 psia (0. 4 bara). There was no pressure regulator on the source and no pressure relief valve on the chamber. The pressure gauge was installed between two chambers with shutoff valves to each, thus allowing erroneous pressure readings under dynamic pressure conditions. CONTRIBUTING CAUSE was a failure to follow procedures in checking leaks.