HIAD Event Initiating System: Hydrogen System Initiating Event


In a fertilizer manufacturing plant, a gas leak occurred at an ammonia unit heat exchanger located in a ventilated area outside. The operator partially stopped the unit, set up steam hoses and…
A leak occurred on a relief valve of a high pressure hydrogen storage tank. No explosion or fire occurred.

The release occurred during refuelling of the mobile storage system. This operation was part of a series of tests aiming at verifying the tightness of the system. When opening a valve to connect…

Leakage of gas from blow-off pipe for depressurization while filling hydrogen in cylinder.
A hydrogen leak occurs at on the hose connection of a tube trailer being loaded into an industrial gas company. Alerted by the noise, the driver of the vehicle gave the alert. Firefighters from the…
At a linear accelerator site, a hydrogen retort exploded during ignition of burn-off gas. One employee experienced hearing loss in one ear and a shoulder injury from being blown into a cabinet. A…

The incident occurred at a plant manufacturing polymer batteries, audio and GPS systems. As consequence of the great tohokyu earthquake and tsunami, a pipe of a hydrogen tank started leaking,…

A hydrogen tank exploded and caught fire at a chemical plant.

Hydrogen caused an explosion at a power plant, killing two people and injuring 13 others. The station was subsequently shut down. The cause of the explosion was not reported. At first, sources…

While travelling to deliver liquid hydrogen to a customer, a tanker experienced an increase of the internal pressure of the cargo tank. The drivers pulled off the road and at that moment the…

An explosion occurred at a hydrogen boiler of a chemical manufacturing plant producing hydrogen gas and other substances. A potential flow restriction in the feed line to a hydrogen-fired boiler…

The incident involves a gas booster provided by a manufacturer. This device is used in the experimental platform of the project to raise the pressure in pipelines from 60 to 80 barg (from 6 to 8 MPa)…
The event occurred in a university research building dedicated to the study of the take-off of space launchers . An operator gave the alarm during the hydrogen pressure pre-setting phase. he had seen…
A hydrogen explosion occurred on a furnace in a company of copper metallurgy. The incident occurred at the end of the production cycle, when the furnace bell is lifted at the end of the cooling…

Test facility H2 vent line exploded destroying about 150 feet of line. The flare stack was on at the time. [Ordin, NASA (1974)]

A leak occurred at a dispenser hose of a hydrogen refuelling station. On the day of the accident six FCVs had already been filled. Four minutes after the start of the filling of a seventh vehicle,…

A leak started on the hydrogen coolant cicrcuit of one of the power generators of the plant. It was indirectly detected because f the increased need to generate new hydrogen for cooling and it…

During a transfer of liquid hydrogen from a commercial tanker to a stationary receiving vessel, a leak developed in the bayonet fitting at trailer-vessel connection. The leak produced a hydrogen…

This accident occurred at the unit producing synthetic adhesives by adding hydrogen to petroleum resin under high temperature and pressure. Hydrogen was added to the reaction via a supply pipe at the…
A truck transporting a pallet of 30 compressed hydrogen cylinders was traveling on a highway when gas started leaking from the welded pipe. The fire department ordered the hydrogen in to be released…