Skip to main content

HIAD Classification of the Physical Effects: Hydrogen Release And Ignition


Five barrels of aluminium dust that had been removed from an outdoor dust collector were sealed and stored in the plant adjacent to electrical panels. One of them had somehow been contaminated with…
In this plant, after conversion of the major part of the carbon dioxide into urea, the off-gasses from the reactor consist of ammonia, carbon dioxide, hydrogen, oxygen and nitrogen. Prior to venting…
At an agrochemical plant, an explosion occurred near a drained hydrofluoric acid tank, when 4 employees were welding on adjacent pipelines. An investigation was launched to determine this accident’s…
An explosion occurred in the teat treatment workshop of this site. The explosion was centred in the electrical control panel of the High Velocity Oxy Fuel (HVOF) thermal spraying equipment. The…

An internal explosion occurred in a cone-roof gas oil tank. The explosion completely ruptured the weak roof-to-shell weld seam and projected the roof into the diked area beside the tank. The…

In a chlorine manufacturing unit, an explosion occurs in the room of the electrolysis cells. The accident occurs during the start-up phase of the unit, it is due to the presence of hydrogen in the…
During functional tests of the system, a major quantity of hydrogen-containing gas was released from an adsorber, followed by its ignition. After the alarm was released the feed of the adsorber was…

An explosion occurred in an industrial cleaner, blowing off and shattering the cover from the top of the machine. It is believed that the explosion was caused by accidental formation of hydrogen…

The Microbiological Anaerobic Chamber of approximately 2 m3 capacity was containing an explosive mixture of hydrogen and air. A fire followed the explosion, but was rapidly extinguished by staff…

During a test in which GH2 was driving gas, an explosion occurred in the test section. The drive chamber was over-pressurized to 3500 psi (240 bar). The test section failed; windows designed for a…

Fire in bulk hydrogen storage compound. Pressure gauge shut off valve spindle blown out (could be completely unscrewed and removed). The subsequent leak ignited by unknown source. No injuries…
The incident occurred at a caustic soda electrolysis plant. A chlorine suction pump failed on a sodium hydroxide electrolysis unit. The arrest of the pump caused the stop of the electrolysis current.…

A fuel cells and hydrogen city bus was refuelling at a hydrogen refilling station. It had just terminated this operation and the engine was restarted, that an explosion occurred at the back of the…

In a graphite purification workshop, the cooling circuit of an electric furnace leaks, the water decomposes in contact with materials heated to a temperature of 1,800°C; the gas mixture (hydrogen,…
Explosion in a chemical manufacturing plant for the pharmaceutical and cosmetics industries, classified as Seveso high level,The explosion occurred in the hydrogenation reactor, when opening two…
Explosion in a food products plant (Seveso classified) The event occurred in the settling cyclone of a hydrogenation reactor of a starch production unit. The process consisted in introducing the…
The accident occurred during the night during the production of a silicon oil- and additive-based waterproofing agent. A junior technician (hired 6 months back), recently assigned to this post, was…
In a chemical plant, an explosion occurred on the primary reformer of an ammonia manufacturing unit.
A major leak (estimated between 1. 5 and 3 kg) of hydrogen from high-pressure storage, resulted in a detonation, from hydrogen a refuelling station. Causes were two untightened bolts securing the…
An in-tank explosion occurred in a gaseous waste decay tank while the plant was in cold shutdown. The gaseous hydrogen present in the tank formed a flammable mixture and ignited due to air…