Skip to main content

Explosion in industrial cleaner (293)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion in industrial cleaner

An explosion occurred in an industrial cleaner, blowing off and shattering the cover from the top of the machine. It is believed that the explosion was caused by accidental formation of hydrogen from the rest of previous cleaning (probably from NaOH). One person injured.

Event Date
July 26, 2000
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Facility Information
Application Type
Application
Industrial cleaner
Specific Application Supply Chain Stage
Components Involved

Site industrial cleaner.

Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary

The cleaning machine was thought to have been used to remove coolant & swarf from a machine used for aluminium turning. The same machine was then used for removing wash water from another machine which was very slightly contaminated with an alkaline solution (probably the NaOH) It is thought this reacted and caused a build-up of hydrogen gas.

Consequences
Number of Injured Persons
1
Number of Fatalities
0
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Event description provided by HSE, original source confidential