HIAD Classification of the Physical Effects: Hydrogen Release And Ignition


The incident involved an hydrogen-on-demand unit (HOD), which was installed inside an environmental test chamber used for reliability tests. An employee was troubleshooting the chamber, assessing the…
A crack occurred in a storage tank (300 kg of hydrogen) releasing gaseous hydrogen to atmosphere. The vapour cloud exploded with an apparent centre of explosion 9 m above ground, with a energy…

A hydrogen explosion occurred at a company producing soyabean oils. The exact location and causes are unknown, the only fact being reported was that the hydrogen involved a hydrogen tank…

In an electricity production plant, hydrogen leaked from a tank supplying the colant to the generator. The leaked hydrogen iognited and formed a fireball. Possible involvement of sealing oil not…
An explosion occurred in a pipe system carrying hydrogen and methane at an ammonia plant. No major injuries have been reported.
The accident occurred when a welder belong to a sub-contractor company was working on tank roof. The zeolite crystallisation tank was being cleaned out with approx. 20% sulphuric acid. It was not…

An explosion of hydrogen gas occurred on a test bench at a factory manufacturing rocket engins. The effect was perceived several kilometres away. The explosion was caused by the release of 8 kg of…

While preparations were being made for a LH2 turbopump test, an explosion occurred above the test cell. Major damage was caused throughout the test facility. A short duration fire caused minor…

A special test was being executed to evaluate a high-pressure fuel turbo-pump lift-off seal. During the test, an open-air explosion took place on the test stand. There were no injuries, but non…

The event started when a gasket in a water pump was blown out. The water pump was situated inside a 100 m long, 10 m wide, and 7 m high building. The pump was feeding water to a vessel containing…
An explosion, accompanied by abundant black smoke, occurred at an ammonia production plant. An ignited leak of hydrogen in the ammonia production unit had spread to the pressure circuit carrying…
The incident occurred at the hydrogen coolant system of the power generator. The control panel door for the 32 hydrogen dryer blew off due to a small hydrogen explosion. No one was injured in the…
The release and fire occurred during what appeared to be a normal operation in a reactor section of a Residue Hydrotreater Unit, when an eight-inch pipe connected to a heat exchanger failed at the…
The explosion followed a hydrogen leak on a unit conditioning hydrogen. The leak was caused by the mechanical rupture of the membrane of a pressure release device which was part of a pressure…

[Note HIAD validator: this an incident where the hydrogen systems were invovled as effects of the initiating event. There is nevertheless and addtional possible contribution by hydrogen…

An explosion occurred during calibration of engine. The equipment was covered by a shed and when the valve was operated allowing hydrogen gas to flow through the engine, the gas ignited. The…

After completion of a process using hydrogen an explosion occurred in the vicinity of the vent stack. Cold hydrogen gas was being vented into the atmosphere for about 45 minutes. The weather was…

A process operator was working on a hydrogen tank in a mechanical workshop. The goal of the onoging operation was the removal of the collar from a hydrogen cylinder. An electric crosscut saw was used…
Several explosions occurred in one of the catalytic reforming units of the refinery, followed by a fire in the same unit. The fire derived from the explosions lasted for almost one day. The…

A series of explosions occurred in thee desulphurisation and catalytic reforming unit of the refinery, followed by fires in the same unit. The establishment is classified as Seveso Upper Tier…