The event occurred at an ethylene production plant. The plant was shutdown at the time as the supply of compressed air to the gauges had inadvertently been switched off. This failure of the air…
The incident at a bio-fuels research laboratory occurred when a visiting research fellow was transferring hydrogen, oxygen and carbon dioxide from compressed gas cylinders into a low-pressure mixing…
A violent explosion occurred at a blast furnace. The explosion occurred while the blast furnace was being cleaned at the end of casting. For this purpose, worker poured the contents of a casting…
SUMMARY The explosion occurred in a catalyst regenerator of the catalytic cracking unit in a fluidized bed during a technical shutdown. A few seconds later, a second explosion is perceived, it is the…

[Note of the event validator: according to the sources, hydrogen as combustible gas does not seems to have plaid part in this incident. However, it is more plausible that hydrogen, as the main…

An explosion occurred at a chlorine production plant during the restart of the installation. An hydraulic syphon had probably been blocked by fire extinguishing products following a previous fire on…

The incident occurred at a dispenser of a hydrogen refuelling station (HRS). The HRS employee had just terminated the filling of a fuel cell vehicle (FHV) and was depressurising the filling hose,…

On a cold morning, the gasoil hydro-treatment unit was being brought back on line after being out of service to repair a governor problem on the recycle gas compressor. Several upset trips had…
Five workers were in the process of trouble shooting a hydrogen compressor. No actual work was in process, but the compressor had still hydrogen in the lines. The three were only listening for…

The explosion occurred at a sand oil an explosion and affected the hydrogen compressor and its building, serving the hydrocracker unit. (1) More than two months before the incident, a large…

Two employees were working on a electric furnace under hydrogen atmosphere that had jammed. The furnace exploded. The employees sustained flash burns to their faces and were taken to the hospital,…
The explosion occurred at the hydrogen producing unit of a refinery. A solution of potassium carbonate was being drawn off from an absorption tower to a temporary storage tank for a turnaround…
An explosion took place at a research facility of a university, due to an accidental release of hydrogen. Hydrogen gas was used in research reactors to deposit amorphous silicon thin films. The…
Employee #1, a maintenance worker, was killed by a hydrogen blast while working inside a batch hydrogenation unit.
The day before the incident, the outlet pipe connected to methanation reactor started leaking gas, which contains hydrogen. The leak was temporarily eliminated by a pressurised plug. On the day of…
The event occurred in the steam condensing line of the residual heat removal system the nuclear reactor. Radiolysis generated hydrogen and oxygen, which then accumulated in high concentration in the…
A gas mixture (25% nitrogen, 73% of hydrogen, 2% methane) leaked, due to the ejection of the check valve from its connection with the inlet pipe. A large amount of the gas mixed with air and ignited,…
At a rubber factory, an explosion occurred inside a lubricant container filled with 18 tonnes of tri-(nonylphenyl) phosphate (TNPP or TNPA). This tank was typically stirred and maintained at 45°C.…
An explosion and fire occurred at a chemical plant applying silicone coatings. The blast occurred when some polymethyl hydrogen siloxane was accidentally fed into a reactor, together with the correct…
An explosion occurred at testing facility of a space rocket engine. The incident occurred when executing a test studying the performance of a hydrogen gas flow measuring system for fuel feeding…