The DC power system was serving as back-up power and was based on a battery storage system. It had been taken off-line to be replaced with a more modern system. After its replacement, at the…

This incident occurred when subcontractor two workers were widening air vents on the roof of a building hosting a tank containing hydrogen chloride solution. This intervention was necessary to to…
A release of "synthesis gas", containing primarily hydrogen occurred at the ammonia synthesis unt of a fertilisers plant. The location of the leak was a valve within the ammonia synthesis column. The…
This incident occurred unit at a demonstration of a new technology for the catalytic cracking of vacuum residual oil. An oil storage tank failed due to high pressure. The overpressure in the tank was…
The incident occurred at an indirect oil desulphurisation unit, and originated on a piping at the outlet of a heat exchanger. The exchanger was located in the furthermost downstream of the reactor.…
The incident occurred at a tank of the chlorine electrolyser of a water treatment plant The plant products were sodium hypochlorite as a disinfectant for water treatments. The production process used…
An explosion occurred a the Lurgi electrolyser of a chemical factory. The plant suffered extensive damage and one man died. The investigation concluded that the explosion probably occurred on the…
The explosion occurred inside the lower hydrogenation tower of a hydrogen peroxide unit, damaging the distribution tray inside the tower. it caused 4 fatalities, 2 injuries and considerabledamage to…

A hydrogen explosion occurred at the hydrogen storage unit of a power generation plant. A burst disc opened, releasing approximately 3 tons of hydrogen. The leaked hydrogen formed an explosive…

An explosion and fire occurred at night inside a unit for the synthesis of toluene di-amine. The process implied the hydrogenation of di-nitrotoluene in presence of isopropanol as solvent and Raney…
This report consists of two events: B. On February 23, 2004, one person was injured, apparently lightly, in a fire that broke out following a hydrogen explosion, at Herzliya Pituah, Israel . An…
At a soaking facility of an industrial plant in the metallurgy sector, the pipeline between a supply tank and a feed pump became clogged and the autoclave only received sporadic feed. Problems had…
on a Sunday morning, in a ceramic factory, a leak on a 100 m³ tank containing 370 kg of hydrogen caused an explosion. The generated pressure wave causes significant damage to exterior buildings…
Hydrogen ignition during the (illegal) filling of a balloon. Two men had decided to fill in a weather balloon with hydrogen in a storeroom located in the basement of a block of flats. Their idea was…
A hydrogen explosion occurred at a 585-MW coal-fired supercritical unit and caused one fatality, injuries to 10 other people, and significant damage to several buildings. The explosion occurred…
This event occurred when a hydrogen-carrying trailer was supplying hydrogen to a chemical plant. Instead of filling the hydrogen stationary storage, large quantities of hydrogen were transferred from…
A welder was welding a stainless steel drain pipe with an arc welder, above a sulphuric acid storage tank. When he lowered the pipe, the hydrogen gas in tank ignited causing an explosion and one…
Two explosions rocked the industrial area of Santa Clara afternoon June 1st 2019, sparking a smoky fire at a chemical, gas storage and transportation facility of Air Products and Chemicals Inc. near…
A blowback occurred when adding iron powder to an EDTA solution at 60 C in a chemical reactor (EDTA = Ethylene-diamine-tetra-acetic acid ). Hydrogen was produced by a chemical reaction and ignited by…
An explosion occurred caused by a leak of hydrogen from a reactor on a fertilizer plant. The blast hurled the head of a hydrogen gas converter 150m and sent it crashing through reinforced-concrete…