Explosion in a food products plant (Seveso classified) The event occurred in the settling cyclone of a hydrogenation reactor of a starch production unit. The process consisted in introducing the…
The accident occurred during the night during the production of a silicon oil- and additive-based waterproofing agent. A junior technician (hired 6 months back), recently assigned to this post, was…
The event occurred in an atmospheric pressure tank storing effluents. The plant was in the production phase. The head of the overfill prevention valve located at the top of the tank was thrown a…
The boat was a 6. 5 m semi-rigid electric-powered inflatable canoe, mainly used for greeting and directing pleasure boaters in harbour. It exploded without a flame shortly when an employee of the…
An explosion occurs in the oxygen gas holder in an electrolysis plant. The explosion was due to the entry of hydrogen in the oxygen gas holder. The dome of the gas holder and the collar were blown…
An explosion occurred in a pipe system carrying hydrogen and methane at an ammonia plant. No major injuries have been reported.
An explosion, accompanied by abundant black smoke, occurred at an ammonia production plant. An ignited leak of hydrogen in the ammonia production unit had spread to the pressure circuit carrying…
The explosion followed a hydrogen leak on a unit conditioning hydrogen. The leak was caused by the mechanical rupture of the membrane of a pressure release device which was part of a pressure…
Several explosions occurred in one of the catalytic reforming units of the refinery, followed by a fire in the same unit. The fire derived from the explosions lasted for almost one day. The…
A tank of liquefied hydrogen felt down in a chemical plant. The tank, containing 100 m³ of liquid hydrogen, was installed on a concrete plate, which failed. The hydrogen started leaking from the…
The incident happened in an ammonia plant, on the pipe leading hot synthesis gas (syngas) from the synthesis convertor to the first heat exchanger. The pipe cracked, releasing the syngas which did…
Two successive fires broke out in an interval of few minutes in four cells in the electrolysis room of a chlorine production plant. The technicians brought the fire under control using the fire…
Chlorine was released in the liquefaction unit of a chlorine electrolysis plant, due to the rupture of a pipe. During the re-start phase of an electrolysis workshop in a chemical plant, chlorine (Cl2…
A fire occurred on a flange of a hydro-desulphurisation unit during start-up operations. A failure of this flange caused of the leak.
A fire occurred on a valve of a hydro-desulphurisation unit in a refinery. The failed gland was modified and fire extinguishers by steams were installed permanently .
The fire started in a electrolysis cell. The fire originated from a hydrogen leak in the hydrogen over pressure control system of the cell and an unidentified ignition source. The ARIA report (sew…
A fire developed at the top of the flare stack of a during a violent thunderstorm, in a chemical plant (Seveso-classified). The flare stack is used to discharge hydrogen produced by the restarting of…
A hydrogen leak occurred in in the cooling system of electricity generation part of the in a nuclear power plant. .
The ignition of a hydrogen leak occurred at a semitrailer connected to a pressure reducing station, while waiting a transfer. The alert was given by personnel of the company cafeteria located nearby.…
Hydrogen leakage occurred on a pipe flange in an ammonia synthesis unit. A fire started immediately, which was taken under a control before the arrival of firefighters.