Skip to main content

Regions and Countries: France


A liquid hydrogen leak occurs in a steel plant on a 42000 l tank of liquid hydrogen. A sealing coupling was installed to stop the leak.
A hydrogen leak occurred on a flange located on a pipe coming from the hydrogen storage tank. The staff was confined and the Internal Operation Plan was launched. Helium was injected in the tank and…
A small release of hydrogen occurred after the collision between a truck containing liquid hydrogen and a truck containing manganese dioxide on a highway. Due to the release, the traffic was…
A leak occurred on the safety valve of a train wagon transporting liquid hydrogen. The train was composed of 10 wagons. The train was stopped on the railway several hours to allow depressurisation of…
A leak occurred on a rack containing 12 cylinders of hydrogen (50 l at 200 bar each) delivered by a lorry inside the fenced storage area of a bulb manufacturing plant. The plant’s safety manager…
The incident occurred in a plant producing organic chemistry products. Hydrogen leaked briefly from an hydraulic valve. There has been no victim.
A release of hydrogen took place in a metal cold rolling workshop. The hydrogen leaked from a cylinder of 15 m3, which was part of a storage system of 250 m3. Half of the workshop and the surrounding…
A hydrogen release occurred in a storage area of a nuclear power plant. . The storage consisted of three trailers made of 14 compressed gas cylinders each. The cylinders, mounted horizontally, had a…
A hydrogen leak occurred on one of the cylinders carried by a truck. After the leak was stopped, the vehicle was escorted by the fire brigade and taken to a laboratory for inspection. [Nore of the…
The event was initiated by the burst of a rupture disc on a reactor during a hydrogenation process. The hydrogenation reaction occurs under pressure in a tank containing 3,000 l of a mixture of…
The accident occurred on one of the heat exchangers of the hydro-desulphurisation unit. The role of the exchanger , located between the charge pumps and the furnace, was to heat the charge using the…
A hydrogen leak occurs in a manufacture of steel pipes. The leak is detected and the alarm is triggered.
A release occurred following the rupture of a pipe of 250 mm in diameter. 350 kg were released to the atmosphere in 11 minutes, consisting in 80% of hydrogen, 5% of hydrogen sulphide (H2S) and 4% of…
Leakage of a mixture of hydrogen, nitrogen, citric acid, hydrofluoric acid and hydrogen sulphide occurs during ventilation shutdown on high temperature PVC furnaces. The accident follows an…
A six-cylinder rack containing an argon / hydrogen mixture is dropped from a truck on a national highway, causing a gas leak. A security perimeter was set up. The services of the equipment took care…
During a stop of the operations for maintenance and repairs, a worker was cold-cutting a hydrogen piping supposedly purged before. This caused a release of hydrogen. Realising this, the worker…
The operator detected a leak of aerosol hydrocarbons (diesel, hydrogen and hydrogen sulphide) in the diesel desulphurisation unit, causing a release of hydrogen and hydrogen sulphide at the top of…
During a patrol, an operator detects a hydrogen leak in a refinery on a footbridge 30 meters high. The origin of the leak is identified 4 days later on a pipe under insulation. The operator proceeds…
In a fertilizer manufacturing plant, during his inspection round, an operator detected a hydrogen leak at a flange of an exchanger located between the conversion and decarbonisation stages of the…
A 40,000-litre capacity tanker carrying liquid hydrogen tipped over into a ditch on a curve in an intersection while travelling on a municipal road at the edge of town. The lorry had just left a…