Skip to main content

Regions and Countries: France


In a chlorine electrolysis facility, a mixture of oxygen and hydrogen in one of the electrolyser cells a short-circuit ignited causing a deflagration. The cover of the cell was a thin plastic film…
An explosion occurred at a chlorine production plant during the restart of the installation. An hydraulic syphon had probably been blocked by fire extinguishing products following a previous fire on…
At a rubber factory, an explosion occurred inside a lubricant container filled with 18 tonnes of tri-(nonylphenyl) phosphate (TNPP or TNPA). This tank was typically stirred and maintained at 45°C.…
An explosion and fire occurred at night inside a unit for the synthesis of toluene di-amine. The process implied the hydrogenation of di-nitrotoluene in presence of isopropanol as solvent and Raney…
[Note of HIAD Validator: the presence of hydrogen and its role in the explosion is only one of the two possible explanations of this incident] The explosion occurred in a chemical reactor tank of a…
In a chemical plant, a violent explosion took place during the batch production of chlobenzorex from an aqueous solution of sodium borohydride contained in a feed tank on a movable truck. The reason…
During chlorine-alkali electrolysis an accident occurred in which chlorine was released due to a chlorine-hydrogen explosion. The person charged with the control of the measurements was informed by…
The explosion occurred during repair work on a boiler. A technician had previously descaled the device using hydrochloric acid, after which he performed the neutralisation step with soda and drained…
The vent occurred in the ammonia production unit. A minor leak had been detected in a flange on the piping of the ammonia synthesis loop (operating at 250 bar). The company called a specialized…
At 11:15 pm, an explosion followed by fire occurred in the vicinity of the measurement transformer on an isolated 90,000 V electrical oil transformer at a plant manufacturing technical polymers.…
Gaseous hydrogen leaked from an oil pump part of the filling and conditioning system in a industrial gases production plant. The released hydrogen ignited and exploded. The cause has been a human…
In a pharmaceutical company classified Seveso ‘upper-tier establishment’, a deflagration occurs at the end of a hydrogenation reaction involving a chemical raw material, acetic acid, water and a…
Explosion in a fine organic chemical plant (Seveso classified ) The event occurred during the cleaning of a reactor. At the completion of a batch manufacturing of a soft reducing agent, an operator…
A deflagration occurred inside the tank at the start of grinding operations. The tank had contained sulphuric acid. All preparatory procedures had been properly carried out: neutralisation of…
A release of a mixture of hydrogen, nitrogen and ammonia ignited and exploded in the ammonia synthesis unit. The release was due to a cracked pipe and occurred at the level a flange situated at the…
Hydrogen was accidentally produced inside the sealed container containing a used battery. The gas, along 6 days deformed the container. Firefighters equipped with breathing apparatus opened the…
Explosion in an electrolyser producing chlorineThe explosion occurred after the opening of an auxiliary circuit-breaker. The opening of the auxiliary circuit breaker trigger the shut down of the…
In the acid treatment room of a Seveso low-threshold hazardous waste treatment centre, an explosion occurred on a 250 m³ concrete tank containing acid sludge being neutralized. The explosion occurred…
In a graphite purification workshop, the cooling circuit of an electric furnace leaks, the water decomposes in contact with materials heated to a temperature of 1,800°C; the gas mixture (hydrogen,…
Explosion in a chemical manufacturing plant for the pharmaceutical and cosmetics industries, classified as Seveso high level,The explosion occurred in the hydrogenation reactor, when opening two…