Skip to main content

HIAD Specific Application Supply Chain Stage: Hydrogen Storage


This event occurred at a depot site with 20 fuel cell buses are operated by a local bus company. A hissing sound was heard coming from a hydrogen tank at the refuelling facility, and the local fire…

A leak occurred near the bottom of a stationary liquid hydrogen tank with a capacity of a 6,000-gallon. The leak was localised on a valve and was visible due to the air condensation forming white…

This near miss affected a testing installation for liquid hydrogen. A leak was located on a valve installed on a purge line connected with a LH2 storage tank. This shut-off valve served to…

A 9000 gal (34 m3) LH2 storage tank exploded during repair of the vent stack. Few days before the explosion, the tank had been filled with LH2, but later on the hydrogen released and ignited at the…

A rupture disc opened on a 76 m3 (20,000-gallon) liquid hydrogen tank, causing the vent stack to release cold gaseous hydrogen. The gas ignited causing a fire on the vent stack's outlet.…

This near-miss occurred at a company producing compressed gas bottles according to customers requests. When preparing a gas mixture containing oxygen and nitrogen, by mistake hydrogen was added,…

During a welding operation on a LH2 fill line it was discovered that LH2 was still in the tank although it should have been drained. Hence the potential for a major explosion existed. [Ordin, NASA…

A cryogenic hydrogen laboratory had a power outage. The cryogenic hydrogen storage was no longer being cooled, therefore temperatures and pressures within the storage system started rising. There…
The vessel affected by the incident was a gas storage used for the hydro-desulphurisation process. The desulphurisation gas had high hydrogen content. The vessels had cracks in the upper transverse…
The release occurred in the hydrogen storage system of a refuelling station. In the night a leakage occurred at one of the 120 high pressure bottles (800 bar). The leakage occurred at a screwed…
Malfunctioning of the non-return valve of the hydrogen compressor has caused the pressure between the hydrogen bottle and the compressor to rise to the maximum allowed pressure of 275 barg. As a…
A factory was evacuated after a tank began leaking hydrogen. No injuries were reported
Compressed hydrogen was released from a storage system due to the rupture of a Bourdon-type pressure gauge. [Zalosh and Short, 1978]
The rupture disc installed on a liquid hydrogen tank failed, in a plant producing organic chemicals, during the weekly shut down. The hydrogen ignited at the exit of the exhaust chimney. The fire and…
A liquid hydrogen leak occurs in a steel plant on a 42000 l tank of liquid hydrogen. A sealing coupling was installed to stop the leak.

A release occurred from a high-pressure hydrogen storage vessel at a hydrogen refuelling stations. Immediately after detection, hydrogen was vented out as a safety measure. There was no injury,…

The released occurred at a T-coupling small of a small pipe (possibly around 6 mm in diameter) in a gas storage system consisting of 40 vertical steel cylinders of 50 l each in a container. At the…

A hydrogen leak occurred on a flange located on a pipe coming from the hydrogen storage tank. The staff was confined and the Internal Operation Plan was launched. Helium was injected in the tank and…

The release occurred at a composite pressure vessel on the roof of a refuelling station (in the form of a ISO-container). The leak occurred on a treated connection to the vessel. The vessel…

A pipe of a hydrogen storage system (240 m³) breaks. The staff is evacuated and a perimeter of protection is put in place.