Skip to main content

HIAD Specific Application Supply Chain Stage: Hydrogen Storage


on a Sunday morning, in a ceramic factory, a leak on a 100 m³ tank containing 370 kg of hydrogen caused an explosion. The generated pressure wave causes significant damage to exterior buildings…
Flask explosion due to hydrogen in the science class.
A tank leaking hydrogen at an electrical power plant exploded.
Hydrogen escaped when a venting valve was opened for the inspection of a cap. The escaped hydrogen caught fire, resulting in the death of 4 people, injuries to others 3 and damages to the plant.

The event took place in centre for assembly and maintenance of empty gas cylinders. Three workers were dismantling a rack of eight hydrogen cylinders for maintenance. When woeking at the when they…

A major vapour cloud explosion (VCE) occurred at a gas storage tank (a gasometer) of a coking unit. Several days before the incident, several gas detection alarms had frequently sounded. Also, the…

The incident occurred at a hydrogen production plant, consisting of an electrolyser, a gasholder for the temporary storage of the hydrogen, compressors and gas dryers and final storage in four high…

A LH2 tank exploded causing injury and damage when hot wire sensors were used in tank after purging. [Ordin, NASA (1974)]

The event occurred at a hydrogen tank (another source reports a 'conduit in an enclosed space') of a hydrogen generation unit of a refinery. The explosion caused a flare and a displacement of air…
The explosion occurred at the second floor of university building, where a postdoc researcher was conducting a chemical experiment using hydrogen gas in the laboratory. First a chemical fire started…

During welding of a pipe to an existing header vent system, hydrogen gas was ignited. The adjacent vessels and lines were inerted with helium and a hydrogen detection check did not indi­cate…

Fire in bulk hydrogen storage compound. Pressure gauge shut off valve spindle blown out (could be completely unscrewed and removed). The subsequent leak ignited by unknown source. No injuries…
A major leak (estimated between 1. 5 and 3 kg) of hydrogen from high-pressure storage, resulted in a detonation, from hydrogen a refuelling station. Causes were two untightened bolts securing the…
A tank "filled with low-pressure hydrogen" exploded at a food manufacturing plant, killing three workers. The accident occurred when the workers were welding inside the tank after clearing hydrogen…
The accident happened during testing of a hydrogen tank at a company which manufactured valves and other hydrogen-storage components. A dull bang and a huge pressure wave was felt kilometres away.…
3 people were killed when 18 hydrogen gas cylinders exploded.
Hydrogen gas cylinders exploded at the same time in three industrial locations, when the opening valve was opened. The overpressure generated by the explosion caused the walls of the hydrogen…
A crack occurred in a storage tank (300 kg of hydrogen) releasing gaseous hydrogen to atmosphere. The vapour cloud exploded with an apparent centre of explosion 9 m above ground, with a energy…
The event started when a gasket in a water pump was blown out. The water pump was situated inside a 100 m long, 10 m wide, and 7 m high building. The pump was feeding water to a vessel containing…
A process operator was working on a hydrogen tank in a mechanical workshop. The goal of the onoging operation was the removal of the collar from a hydrogen cylinder. An electric crosscut saw was used…