Skip to main content

Near miss due to inadequate purge procedure (391)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Near miss due to inadequate purge procedure

During a welding operation on a LH2 fill line it was discovered that LH2 was still in the tank although it should have been drained. Hence the potential for a major explosion existed. [Ordin, NASA (1974)]

Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

A deviation from procedures had occurred when purging was continued without power to the tank sensing probes in the LH2 tank at the after 400th cycle. Because of the undetected presence of LH2 in the tank, when gaseous nitrogen was introduced, it liquefied and blocked the system.

Facility Information
Application Type
Application
Aerospace
Specific Application Supply Chain Stage
Components Involved

LH2 pipe

Storage/Process Medium
Actual Pressure
0
Design Pressure
0
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Event Nature
Emergency Action

none

Release Type
Ignition Source
References
References

Mishap no 50 in P. L. Ordin, Review of hydrogen accidents and incidents in NASA operations, 1974, NASA TM X-71565 https://ntrs. nasa. gov/citations/19740020344

Lowesmith et al. , Safety issues of the liquefaction, storage and transportation of liquid hydrogen: An analysis of incidents and HAZIDS, Int. J. Hydrogen energy (2014) https://doi. org/10. 1016/j. ijhydene. 2014. 08. 002

Hankinson and Lowesmith, Qualitative Risk Assessment of Hydrogen Liquefaction, Storage and Transportation, FCH JU project IDEALHY, Deliverable 3. 10 (2013) confidential (accessed October 2025)