HIAD Nature Event - Release Type: Liquid-gas mixture


At 11:15 pm, an explosion followed by fire occurred in the vicinity of the measurement transformer on an isolated 90,000 V electrical oil transformer at a plant manufacturing technical polymers.…
This accident took place in different phases and in two different units of a refinery:It consists first in a non-hydrogen accident, followed by a hydrogen-related accident. Before the hydrogen…
The event occurred at the hydrogen production unit of the ammonia production plant. An air-hydrogen mixture formed in the building hosting a water pump which fed water to a vessel that contained…

An internal explosion occurred in a cone-roof gas oil tank. The explosion completely ruptured the weak roof-to-shell weld seam and projected the roof into the diked area beside the tank. The…

In a chemical plant, a 1750 m³ tank containing an ammoniac solution exploded. The anchorage of the tank was ripped, the tank lifted on one side and crashed against the retention wall, which was…

The event terminated an unmanned flight. One of the goals of the mission was to gain experience from re-firing engines in space. It was important to understand better the behaviour of the liquid…

The accident happened in an anhydrous ammonia plant, commissioned in March 1977. Hydrogen accumulated inside a Benfield solution (hot potassium) storage tank and was ignited by a static charge, which…

The incident occurred at the hydrofining unit, refining a mixture of petroleum and diesel into Euro 3 and Euro 4 diesel. A pump feeding the reactor with the process mixture failed. Following the…

The incident involved an hydrogen-on-demand unit (HOD), which was installed inside an environmental test chamber used for reliability tests. An employee was troubleshooting the chamber, assessing the…
It was a small incident in a heat-electric power plant. The alarm was registered at 11:26 and the fire was extinguished at 12:03. The incident took place during tests using the reserve power…

One turbine was stopped for minor repairs and adjustment. The generator’s excitation breaker and air-operated disconnect breakers were opened. When the turbine generator had nearly completed its…

The incident started with the cracking of the low-pressure turbine blades. This caused an unbalance to turbine generator rotor which led to the failure of the bearings and the loss of confinement…

During a turbine testing at 100 percent power, a problem developed in the auto-stop trip system, which led to a turbine and reactor trip. The turbine stop valves closed as expected, but after closure…
A technical failure in the High-Pressure turbine blades caused high vibrations in lubricating oil pipes. Some pipes broke off and the oil leak caught fire from hot surfaces. Also the generator's…

The incident occurred at the power generator of a nuclear power plant, in a non-nuclear area of the plant. Although hydrogen was use in the system, it was not affected by the fire. Oil leaked at a…

This incident occurred at a unit designed to convert heavy oil residues into refined products. It involved a fluidized bed reactor and the related hydrogen supply system serving the optimisation…

When waste alkali solution was taken out of dumper trucks into a waste liquid storage tank, a reaction occurred in the tank. As a result, the solution in the tank foamed over it, and reached an…

During startup of the hydrodesulphurisation unit, diesel and hydrogen leaked from a flange near the heat exchanger. The flammable mixture ignited spontaneously, causing a fire. Plant personnel…

A fire broke out following a hydrogen leak on the Cyclododecane unit in a chemical plant. A plume of smoke became visible outside the site. The fire was brought under control by putting the unit in…

The incident occurred during maintenance works at a hydro-cracking unit of a refinery (the report does not explicitly mention the unit, but it is plausible to assume that it was a hydro-cracking…