Skip to main content

HIAD Nature Event - Flame Type: Other


The event occurred during the decommissioning of a nuclear power plant. It involved a tank containing 100 kg of residual sodium from the decommissioned experimental nuclear reactor which was using…
Heavy rains (more than 600 mm in 1 day) had flood a factory manufacturing calcium core electrical conductors. The power supply was cut off. The water came into contact with the calcium stored in 150…
The event occurred in a silicon hydride (SiH) emulsion production process inside an enclosed production building. The reaction was ongoing when one of the tank started overflowing with foam. The…
The event occurred at one of the unit producing iron powder, consisting of a furnace with a running belt for the powder, kept under hydrogen atmosphere to reduce and purify the metal. The hydrogen…
The incident occurred at the hydro-dealkylation (HDA) plant of an aromatics manufacturer. The affected component was a heat exchanger part of the hydrogen purification system. This part failed…
The accident occurred in the organo-metallic compound production unit, on a transport container for aluminium alkyls, which exploded during a cleansing process at the washing station. The incident…
An explosion or fire occurred in a hydro-treatment unit which was processing Fluid Catalytic Cracking feedstock. It was caused by a failure in a pipe downstream from a separator, resulting in the…
on a Sunday morning, in a ceramic factory, a leak on a 100 m³ tank containing 370 kg of hydrogen caused an explosion. The generated pressure wave causes significant damage to exterior buildings…
The event started at the effluent pipe of one of the hydro-cracking reactors, which broke and released a mixture of hydrogen, light gases (methane, butane), light gasoline; heavy gasoline; gas oil.…
Workers were connecting a compressed hydrogen cylinder, when a release of hydrogen occurred within a safety-box for flammable gases (a safety cabinet). During the emergency response procedures, the…
The fire started in a electrolysis cell. The fire originated from a hydrogen leak in the hydrogen over pressure control system of the cell and an unidentified ignition source. The ARIA report (sew…
A hydrogen leak occurred on the a coolant pipe of an electrical generator located in the turbine building, at 200 m from the reactor. Because of the welding works ongoing at that moment on the pipe,…
SYNOPTICs The loss of the hydrogen side sealing oil pump and other problems in the sealing oil system resulted in the coolant hydrogen leaking from the generator. The hydrogen leaked for several…
At a nuclear power plant, a fire occurred in the station's hydrogen storage facility while the plant was operating at 100% power. The fire was reported to the control room by a non-licensed operator…
An isolation failure in starter coil of the high voltage generator induced an electric arc to the hydrogen supply line, with consequent fire and melting of the line. [Zalosh and Short, 1978]
Employees were refilling a rack of 15 hydrogen cylinders that were connected together on a steel pallet with railings. A leak developed at a valve and the pressurized hydrogen ignited. Operations…
The hydrogen release of a defect valve on the hydrogen supply line ignited due to an unknown cause. The fire caused the melting of soldered joint with consequence additional release of hydrogen at 6.…
This incident occurred at a reactor for the isomerization of wax in a lube oil plant. The high-pressure reactor ruptured during a catalyst activation operation. A hot (400 C) gaseous stream of…
Hydrogen was released into a diesel desulfurization unit, producing a 50-meter-long horizontal torch flame upon ignition. The unit was operating normally. Refinery firefighters responded quickly and…
The accident happened in a refinery unit, constructed ten years before. A pigtail ruptured in a steam reformer for the production of hydrogen, and caused a major fire, which destroyed most of the…