HIAD Nature Event - Flame Type: Other


A short circuit occurred in a bus bar system in a transformer building, causing a fire in adjacent switches. This was followed by the tripping out of the three refinery turbo-alternators, cutting off…
Due to the failure of a exhaust system, compressed hydrogen leaked into an area containing electrical components, with consequent fire. Leakage was allowed when exhaust system failed.
The accident occurred on the hopper fine powders from a pair of cyclones (the hopper is the bottom conical part of the cyclone collecting the powder/dust separated from gas phase). A bursting disc…
The event occurred on vent stack of an ammonia synthesis unit. The release of the gas was more specifically on the water purge line or the hydraulic guard of the vent stack. The process gas…
A severe fire in a hydrogen compressor building in a an oil sands refinery reportedly started in a 1,500 psi (103 bar) lube oil system. Fire fighting was difficult because of 40 degrees F temperature…
A release of hydrogen occurred during the filling of a 28 bottles rack. A worker decided to move the rack from one station to another, due to works ongoing nearby. This movement, even though the hose…
A man was burned when a fire broke out as a hydrogen cylinder was being changed in a governmental research centre. It was reported that the fire was started by a spark from a wrench. The sprinkler…
A diesel and gas leak (H2, H2S, CH4) occurred in a hydrodesulphurization unit (2,200 t/d). The leak location was on one of the boiler valves of the stabilization column. The released mixture (390 °C…
An explosion and fire occurred at a reciprocating recycle hydrogen compressor during commissioning of a new Diesel hydrotreatement Unit. It happened during the reactor pre-sulphidisation step, when…
The fire broke out in the acid etching tank of the ferric chloride manufacturing unit of a SEVESO-classified chemical plant. In this tank, the attack reaction of the iron metal with hydrochloric acid…
A hydrogen leak occurred on the hydrogen line of a hydro-desulphurisation unit, followed by ignition . The failure was located on a supply manifold of the unit at a support beam. The unit was shut…
Hydrogen leaked from an analyser of a unit for the production of sodium chlorate. Thehydrogen ignited. On-site staff isolate the leak very quickly, so that the amount of hydrogen released was…
The event occurred in a desulphurisation unit for heavy oil (hydro-cracking, Isomax process). The hydrogen released from one of the heat exchangers where the feed gases are pre-heated by the reactor…
Hydrogen leaked and ignited on a cell in the sodium chlorate (NaClO3) workshop of a chlorinated products plant. There were no victims and no damage to the environment. On-site firefighters controlled…
The fire took place during maintenance works in one out of the three gas extractors of the coke process line. Main cause was displacement of a flange which allowed the entrance of flammable mixture…
A liquid hydrogen trailer-tractor was traveling north on a highway, when the traffic started backing up. The driver put on flashers to warn other motorists to slow down. Nevertheless, a second…
a hydrogen recycle compressor shut down unexpectedly, resulting in flaring activity with visible smoke.