Skip to main content

HIAD Facility - Storage Medium: Gas


A runaway chemical reaction happened in a reactor containing methanol and a substance to be hydrogenated. A large quantity of hydrogen was released; a balloon containing a borohydride exploded.…

The explosion occurred while restarting the ammonia reactor. Synthetic gas (70% H2) was released at the flange of the relief valve of the turbo-compressor. The explosion was followed by a jet fire.…
The incident affected the raw material buffer tank (design pressure 0. 38 MPa) of a diesel hydrogenation unit in a refinery. This buffer tank is located between the hydrogenation reactor and the raw…
The event occurred at one of the unit producing iron powder, consisting of a furnace with a running belt for the powder, kept under hydrogen atmosphere to reduce and purify the metal. The hydrogen…
An explosion and a fire occurred at at a hydro-treatment unit of a chemical plant for lubricants. Plant own emergency response team was activated, assisted from local fire and emergency Services and…
The incident occurred at the hydro-dealkylation (HDA) plant of an aromatics manufacturer. The affected component was a heat exchanger part of the hydrogen purification system. This part failed…

An explosion and fire broke out at a heavy oil direct desulfurization unit at a refinery. The location of the explosion was approximately at 20 meters height. The fire burned within a radius of…

The explosion occurred in the compressors unit of the plant. Witnesses reported a cloud of yellow smoke and a fire ball at its bottom. This first event was followed by a fire fed by a hydrogen pipe…
A syngas leak (hydrogen + methane) occurred at exit of the ammonia production reactor and led to an explosion followed by a fire. The start point of the sequence of events was the syngas at the…
The incident occurred in a hydrocracker unit of the refinery. A control valve on the liquid line between the high- and the low-pressure separators was erroneously opened and the liquid allowed to…
The incident occurred in the hydrogenation unit of a non-further specified chemical plant (SEVESO facility). The hydrogenation unit was probably part of the phenols processing. Before the occurring…
An explosion followed by a fire occurred at a tar precipitator of gas treatment of a coke oven. The extractors were manually activated. Ten minutes later, the operator activates the internal…
The explosion occurred in a benzene production unit (Litol process), which was being restarted following a scheduled shutdown for maintenance. About 30 kilograms of hydrogen gas were relesed into a…
At the time of the incident, the desulphurisation unit was shut down for scheduled cleaning of a cooling tower with reintroduction of a gas mixture into the system at a high hydrogen content. The…
The incident at a bio-fuels research laboratory occurred when a visiting research fellow was transferring hydrogen, oxygen and carbon dioxide from compressed gas cylinders into a low-pressure mixing…
A violent explosion occurred at a blast furnace. The explosion occurred while the blast furnace was being cleaned at the end of casting. For this purpose, worker poured the contents of a casting…
SUMMARY The explosion occurred in a catalyst regenerator of the catalytic cracking unit in a fluidized bed during a technical shutdown. A few seconds later, a second explosion is perceived, it is the…

[Note of the event validator: according to the sources, hydrogen as combustible gas does not seems to have plaid part in this incident. However, it is more plausible that hydrogen, as the main…

In a chlorine electrolysis facility, a mixture of oxygen and hydrogen in one of the electrolyser cells a short-circuit ignited causing a deflagration. The cover of the cell was a thin plastic film…
This incident occurred at a chlorine production plant. A number of minor explosions occurred in the interrupter pot on a chlorine cell of the electrolyser. No injuries or damage were reported. No…