A release occurred from a high-pressure hydrogen storage vessel at a hydrogen refuelling stations. Immediately after detection, hydrogen was vented out as a safety measure. There was no injury,…

A small release of hydrogen occurred after the collision between a truck containing liquid hydrogen and a truck containing manganese dioxide on a highway. Due to the release, the traffic was…
A leak occurred on the safety valve of a train wagon transporting liquid hydrogen. The train was composed of 10 wagons. The train was stopped on the railway several hours to allow depressurisation of…

A pipe of a hydrogen storage system (240 m³) breaks. The staff is evacuated and a perimeter of protection is put in place.

A leak occurred on a rack containing 12 cylinders of hydrogen (50 l at 200 bar each) delivered by a lorry inside the fenced storage area of a bulb manufacturing plant. The plant’s safety manager…
The vent occurred at a hydrogen refuelling station (HRS) of a research laboratory (not public) serving heavy- and light-duty vehicle. The affected dispenser was a 700-bar dispenser for light-duty use…
The accidental hydrogen release occurred when testing the storage system connected to a PEM electrolyser. The leak test consisted in filling the storage with hydrogen at step-wise increase of…
A hydrogen release occurred in a storage area of a nuclear power plant. . The storage consisted of three trailers made of 14 compressed gas cylinders each. The cylinders, mounted horizontally, had a…
Following the breakdown of a piston rod, a mixture of hydrogen and light hydrocarbons was released from the fresh hydrogen compressor of an oil refinery. The rod broke down because of stress…
During the start-up operation (phase) of a cryogenic unit, a separator exploded, releasing ethane, ethylene, methane and hydrogen. The bursting of a tank was caused by a 1600 mm long incipient crack…
A hydrogen safety sensor went into alarm at a hydrogen demonstration facility. The early morning temperature was near freezing and there was a trace of precipitation on exposed surfaces. Upon further…
A hydrogen leak occurred on one of the cylinders carried by a truck. After the leak was stopped, the vehicle was escorted by the fire brigade and taken to a laboratory for inspection. [Nore of the…
The accident occurred on one of the heat exchangers of the hydro-desulphurisation unit. The role of the exchanger , located between the charge pumps and the furnace, was to heat the charge using the…
A release occurred following the rupture of a pipe of 250 mm in diameter. 350 kg were released to the atmosphere in 11 minutes, consisting in 80% of hydrogen, 5% of hydrogen sulphide (H2S) and 4% of…
A six-cylinder rack containing an argon / hydrogen mixture is dropped from a truck on a national highway, causing a gas leak. A security perimeter was set up. The services of the equipment took care…
During a stop of the operations for maintenance and repairs, a worker was cold-cutting a hydrogen piping supposedly purged before. This caused a release of hydrogen. Realising this, the worker…

A hydrogen release occurred at hydrogen storage unit of a manufacturing plant in an urban area. The storage unit was a 9,000-gallon (34,069-liter) liquid hydrogen storage vessel. Its internal…

30 bottles with compressed hydrogen fell from a truck at a junction, because of speeding. The bottles started releasing hydrogen. Emergence team was called, and leak was stopped.
A hydrogen leak was discovered inside an auxiliary building of a nuclear power plant recently licensed. The plant had never reached criticality and was in cold shutdown at the time of the event. The…

Safety disc ruptured on LH2 tanker during offloading. The supply was refused due to possible contamination. [Ordin, NASA (1974)]