HIAD Event Initiating System: Event Initiated by a System Containing also Hydrogen


Workers were performing demolition on a disused furnace. While removing a 10 inch valve from a pipe used to supply coke gas fuel to the furnace, flammable liquid was unexpectedly released and ignited…
The explosion occurred in the ammonia/hydrogen separator of the ammonia reactor due to metallurgical problem.
A mechanical failure occurred in a gasification reactor, which caused a violent (abrupt, sudden) depressurisation of the reactor. The consequences were the projection of tiles of the refractory…
An explosion occurred in an electrostatic precipitator whilst it was being accessed for maintenance. The explosion caused an inspection hatch cover, which had been unbolted, to be blown off and…
In this plant, after conversion of the major part of the carbon dioxide into urea, the off-gasses from the reactor consist of ammonia, carbon dioxide, hydrogen, oxygen and nitrogen. Prior to venting…
In a chemical plant, an explosion occurred on the primary reformer of an ammonia manufacturing unit.
The pressure vessel in a chlorine separation system exploded after the corrosion of the steel process equipment allowed chlorine and hydrogen to mix and form a volatile mixture. The chlorine…
The incident occurred in a catalytic reforming unit. At 13:41, a leak occurred at the 90° elbow of a pressure pipe containing a mixture of hydrogen and naphtha. This pipe was located between the pre…
The event started at the effluent pipe of one of the hydro-cracking reactors, which broke and released a mixture of hydrogen, light gases (methane, butane), light gasoline; heavy gasoline; gas oil.…
A serious chemical accident occurred at chemical industry producing olephins and phenols. The accident resulted in injuries to several workers and extensive damage to the plant, as well as minor…
A section of effluent piping ruptured on the hydrocracker reactor of a refinery. A mixture of light gases (methane, butane), light and heavy gasoline, gas oil and hydrogen was released from the pipe…

The incident occurred at a heat exchanger involving gas-product mixture. The source does not specify the process, with as main component a furnace, probably a hydrodesulphurisation reactor. Due to…

The loss of control of a reaction caused a fire in a pharmaceutical plant caused a reaction runaway and the rupture of a 6 m³ reactor. A cloud containing sodium borohydride and hydrogen was emitted.…

The incident occurred at the hydrofining unit, refining a mixture of petroleum and diesel into Euro 3 and Euro 4 diesel. A pump feeding the reactor with the process mixture failed. Following the…

A series of explosions occurred in thee desulphurisation and catalytic reforming unit of the refinery, followed by fires in the same unit. The establishment is classified as Seveso Upper Tier…

The accident occurred in the Reactor 6 used to carry out the hydrogenation of a pharmaceutical intermediate. The operation of the plant was organized in two shifts. Since the hydrogenation at Reactor…
The incident happened in an ammonia plant, on the pipe leading hot synthesis gas (syngas) from the synthesis convertor to the first heat exchanger. The pipe cracked, releasing the syngas which did…
The explosion and fire happened in a diesel hydro-treatment unit used to desulphurise raw diesel be means of hydrogen. The facility was expected to begin full commercial operations later in 2020.
A fire occurred on a flange of a hydro-desulphurisation unit during start-up operations. A failure of this flange caused of the leak.
A fire occurred on a valve of a hydro-desulphurisation unit in a refinery. The failed gland was modified and fire extinguishers by steams were installed permanently .