Explosion of a chlorine distillate tank of a chemical plant

The pressure vessel in a chlorine separation system exploded after the corrosion of the steel process equipment allowed chlorine and hydrogen to mix and form a volatile mixture. The chlorine receiving tank ruptured violently into five pieces (three large ones and two smaller) causing considerable damage to nearby equipment. The appearance of the pieces confirmed that a the tank had failed by a rapid brittle fracture. The large size of the pieces and the degree of external damage implied a vapour-phase explosion rather than a more energetic liquid-explosion. No organic material traces were detected so that hydrogen became the only possible responsible of explosion. A possible source was found in the corrosion of the steel packing below the feed point of the distillation column. It was not possible to identify a credible ignition source as in most previous chlorine-hydrogen explosions.
Event Date
January 1, 1973
Record Quality Indicator
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITATING CAUSE was the generation and ignition of an explosive atmosphere in the chlorine tank. The composition of this explosive atmosphere could only be guessed. From the analysis of the explosion debris, a vapour phase explosion appeared more plausible than a liquid one. By exclusion, the culprit could be found in the generation of hydrogen from corrosion of steel. if this was the case, lack of inspection could be the ROOT CAUSE.
Facility Information
Application Type
Application
Chlorine production
Specific Application Supply Chain Stage
Components Involved
chlorine tank, chlorine distillation column
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Event Nature
Release Type
Release Substance
H2, Cl2
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Loss Prevention, Vol. 7 (1973), pp. 104-107. American Institute of Chemical Engineers (AIChE) .