HIAD Event Initiating System: Event Initiated by a System Containing also Hydrogen


The fire took place during maintenance works in one out of the three gas extractors of the coke process line. Main cause was displacement of a flange which allowed the entrance of flammable mixture…

A leak occurred on hydrogen compressor in a plant of production of renewable hydrogen. A pipe on the condensate purge circuit of the compressor ruptured, releasing hydrogen and producing a noise…

A mixture of mainly carbon monoxide and hydrogen was released from a pipeline transferring process gases in a not further specified unit of a chemical plant, generating a flammable mixture which…
An explosion occurred in the transformation section of a fertiliser manufacturer, resulting in 8 deaths and 3 injuries. A leak in the secondary pipeline of the 1st conversion system, and caused the…
The incident occurred during the start-up after a routine repair of the refinery's heavy oil hydrodesulfurization system. A valve at the inlet pipe of a high-temperature and high-pressure separation…
This event regards the degradation of steels used in the heat-exchangers of a reformer of a refinery. An inspection by non-destructive ultrasonic techniques revealed material degradation of the steel…
A series of explosions at an oil refinery reformer unit caused by a rupture to an 8 inch naphtha and hydrogen feed pipe. Fire officials cited higher than normal line pressures just before the blast.…
During the start-up operation (phase) of a cryogenic unit, a separator exploded, releasing ethane, ethylene, methane and hydrogen. The bursting of a tank was caused by a 1600 mm long incipient crack…
The event was initiated by the burst of a rupture disc on a reactor during a hydrogenation process. The hydrogenation reaction occurs under pressure in a tank containing 3,000 l of a mixture of…
A leak of a flammable mixture of hydrocarbons and hydrogen from a ruptured pipeline caused an explosion and fire, killing one person and injuring forty six. Investigations into the incident found…
A release of contents of a pressure vessel occurred when a longitudinal weld tore open. The vessel had been shut down and had just been put into use again when the incident occurred. The gas mixture…
The leak occurred on the inlet pipe (P=21 bar, T=320°C) of the diesel desulphurization reactor of a refinery. Hydrogen and diesel fuel were released in the gas phase. The hydrocarbons contaminates…
The operator detected a leak of aerosol hydrocarbons (diesel, hydrogen and hydrogen sulphide) in the diesel desulphurisation unit, causing a release of hydrogen and hydrogen sulphide at the top of…
The incident occurred in the hydrogenation reactor and products cooling unit. The reactor operated under vacuum conditions and the cooling medium was water. Toxic, flammable and explosive substances…
During the start-up of a propylene hydrogenation reactor, very high temperatures were generated in the catalyst bed. At the time, propylene and hydrogen were being fed to the reactor which contained…
A petroleum refinery experienced a catastrophic rupture of a heat exchanger in the catalytic reformer / naphtha hydrotreater unit. The heat exchanger catastrophically ruptured because of High…

A fire broke out at an oil refinery and caused a hydrogen reformer to shut down.

The release of a blast furnace gas occurred at a section of pipework, due to the rupture of valve seal. The gas did not ignite and the fire service attended as a precaution. The gas was both…