HIAD Nature Event - Release Type: Gas


The accident occurred when a welder belong to a sub-contractor company was working on tank roof. The zeolite crystallisation tank was being cleaned out with approx. 20% sulphuric acid. It was not…

An explosion of hydrogen gas occurred on a test bench at a factory manufacturing rocket engins. The effect was perceived several kilometres away. The explosion was caused by the release of 8 kg of…

While preparations were being made for a LH2 turbopump test, an explosion occurred above the test cell. Major damage was caused throughout the test facility. A short duration fire caused minor…

The incident occurred at the hydrogen coolant system of the power generator. The control panel door for the 32 hydrogen dryer blew off due to a small hydrogen explosion. No one was injured in the…
The release and fire occurred during what appeared to be a normal operation in a reactor section of a Residue Hydrotreater Unit, when an eight-inch pipe connected to a heat exchanger failed at the…
The explosion followed a hydrogen leak on a unit conditioning hydrogen. The leak was caused by the mechanical rupture of the membrane of a pressure release device which was part of a pressure…

An explosion occurred during calibration of engine. The equipment was covered by a shed and when the valve was operated allowing hydrogen gas to flow through the engine, the gas ignited. The…

After completion of a process using hydrogen an explosion occurred in the vicinity of the vent stack. Cold hydrogen gas was being vented into the atmosphere for about 45 minutes. The weather was…

A process operator was working on a hydrogen tank in a mechanical workshop. The goal of the onoging operation was the removal of the collar from a hydrogen cylinder. An electric crosscut saw was used…

A common vent system was used to connect vent lines from liquid hydrogen storage vessels to the vent stack (which was lit flaring the gas). Low order detonations were observed around the vent…

Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a. m. and was mostly confined to the off-gas system. Damage was relatively minor. The second…

The incident occurred when filling a gaseous tube trailer from a liquid hydrogen stationary storage system. The liquid hydrogen cryogenic pump shaft malfunctioning caused a series of explosions…

Workers were connecting a compressed hydrogen cylinder, when a release of hydrogen occurred within a safety-box for flammable gases (a safety cabinet). During the emergency response procedures, the…

During the J-2 engine testing program, the engine start tank was pressurised. The pressure raised to an excess of 1500 psi (ca. 105 bar). The venting of the tank was attempted but remained…

A steel hydrogen pipeline failed with a circumferential rupture, at a location where a leak had been already detected and repaired. The leak was discovered during a one-call response for planned…

During a test of an 8 foot scale tank loaded with LH2, the tank burst at 77 psi (ca. 5. 3 bar) destroying the test installation. No fire or explosion occurred and the area control was successfully…

This incident consisted in the dropping of a gas cylinder and the release of its content due to stress corrosion

A driver of a fuel cells vehicle terminated the refuelling and drove away without disconnecting the fueling hose from its vehicle. The breakaway of the fueling hose was supposed to open, but did…

Leaking hydrogen ignited a fire that burned several hours at an oil refinery.
An operator had just replaced the ignition port cover on a hydrochloric acid plant burner. Normal start-up was continued by closing the drain valve in the product run off line and opening the…