HIAD Nature of the Consequences: Leak No Ignition


An aerosol of hydrogen, hydrogen chloride and sulphuric acid is released in a plant producing chlorine via electrolysis. The exhaust pipe on the water circuit of the electrolyser was blinded due to…
A release of hydrogen took place in a metal cold rolling workshop. The hydrogen leaked from a cylinder of 15 m3, which was part of a storage system of 250 m3. Half of the workshop and the surrounding…
A hydrogen release occurred in a storage area of a nuclear power plant. . The storage consisted of three trailers made of 14 compressed gas cylinders each. The cylinders, mounted horizontally, had a…
A small hydrogen leak occurred during routine maintenance on an oil refinery unit not in operation.
In a plant manufacturing chlorate products, a hydrogen leak occurred via the water drainage outlet onto the factory floor. Pressure in the hydrogen line increased because the hydrogen pipes were…
A hydrogen safety sensor went into alarm at a hydrogen demonstration facility. The early morning temperature was near freezing and there was a trace of precipitation on exposed surfaces. Upon further…
A hydrogen leak occurred on one of the cylinders carried by a truck. After the leak was stopped, the vehicle was escorted by the fire brigade and taken to a laboratory for inspection. [Nore of the…
The event was initiated by the burst of a rupture disc on a reactor during a hydrogenation process. The hydrogenation reaction occurs under pressure in a tank containing 3,000 l of a mixture of…
The accident occurred on one of the heat exchangers of the hydro-desulphurisation unit. The role of the exchanger , located between the charge pumps and the furnace, was to heat the charge using the…
A release of contents of a pressure vessel occurred when a longitudinal weld tore open. The vessel had been shut down and had just been put into use again when the incident occurred. The gas mixture…
A hydrogen leak occurs in a manufacture of steel pipes. The leak is detected and the alarm is triggered.
A temperature probe on a hydrogen make up gas compressor blew out from its compression fitting. This resulted in a release of hydrogen. The incident occurred due to a fatigue failure of the…
The leak occurred on the inlet pipe (P=21 bar, T=320°C) of the diesel desulphurization reactor of a refinery. Hydrogen and diesel fuel were released in the gas phase. The hydrocarbons contaminates…
A release occurred following the rupture of a pipe of 250 mm in diameter. 350 kg were released to the atmosphere in 11 minutes, consisting in 80% of hydrogen, 5% of hydrogen sulphide (H2S) and 4% of…
Leakage of a mixture of hydrogen, nitrogen, citric acid, hydrofluoric acid and hydrogen sulphide occurs during ventilation shutdown on high temperature PVC furnaces. The accident follows an…
The release occurred at a dyestuffs intermediates plant. Hydrogen escaped from leak in pipeline connection to a cylinder. Householders nearby evacuated for a short while.
The event occurred at the hydrogenation unit of a pharmaceutical company. 145 kg of hydrogen were released the atmosphere at the gas circulation pump, due to a maintenance error . A specialist…
A six-cylinder rack containing an argon / hydrogen mixture is dropped from a truck on a national highway, causing a gas leak. A security perimeter was set up. The services of the equipment took care…
During a stop of the operations for maintenance and repairs, a worker was cold-cutting a hydrogen piping supposedly purged before. This caused a release of hydrogen. Realising this, the worker…

A hydrogen release occurred at hydrogen storage unit of a manufacturing plant in an urban area. The storage unit was a 9,000-gallon (34,069-liter) liquid hydrogen storage vessel. Its internal…