Release in a chlorine production plant
An aerosol of hydrogen, hydrogen chloride and sulphuric acid is released in a plant producing chlorine via electrolysis. The exhaust pipe on the water circuit of the electrolyser was blinded due to the deterioration of the anticorrosion coating. Hydrogen permeated through the diaphragm and mixed with chlorine.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
According to the ARIA report (see references) the INITIATING cause was the deterioration of an anticorrosion coating, causing the blocking of the water circuit. Although nothing is reported on root cause, inadequate inspection and/or maintenance could have plaid part.