Skip to main content

HIAD Facility - Location Type: Unknown


An explosion and fire occurred in a mud logging unit during the final phase of rigging it up. Gas analysers had been calibrated and the flame ionization detection (FID) and total hydrocarbon analyser…
Explosion in an electrolyser producing chlorineThe explosion occurred after the opening of an auxiliary circuit-breaker. The opening of the auxiliary circuit breaker trigger the shut down of the…
Five barrels of aluminium dust that had been removed from an outdoor dust collector were sealed and stored in the plant adjacent to electrical panels. One of them had somehow been contaminated with…
In this plant, after conversion of the major part of the carbon dioxide into urea, the off-gasses from the reactor consist of ammonia, carbon dioxide, hydrogen, oxygen and nitrogen. Prior to venting…
At an agrochemical plant, an explosion occurred near a drained hydrofluoric acid tank, when 4 employees were welding on adjacent pipelines. An investigation was launched to determine this accident’s…
An explosion occurred in the teat treatment workshop of this site. The explosion was centred in the electrical control panel of the High Velocity Oxy Fuel (HVOF) thermal spraying equipment. The…
During functional tests of the system, a major quantity of hydrogen-containing gas was released from an adsorber, followed by its ignition. After the alarm was released the feed of the adsorber was…

An explosion occurred in an industrial cleaner, blowing off and shattering the cover from the top of the machine. It is believed that the explosion was caused by accidental formation of hydrogen…

During a test in which GH2 was driving gas, an explosion occurred in the test section. The drive chamber was over-pressurized to 3500 psi (240 bar). The test section failed; windows designed for a…

Fire in bulk hydrogen storage compound. Pressure gauge shut off valve spindle blown out (could be completely unscrewed and removed). The subsequent leak ignited by unknown source. No injuries…
The incident occurred at a caustic soda electrolysis plant. A chlorine suction pump failed on a sodium hydroxide electrolysis unit. The arrest of the pump caused the stop of the electrolysis current.…
Static electricity ignited hydrogen in a rising advertising balloon.
Electric spark ignited hydrogen in a captive advertising balloon.
The pressure vessel in a chlorine separation system exploded after the corrosion of the steel process equipment allowed chlorine and hydrogen to mix and form a volatile mixture. The chlorine…
Huge explosion of liquid chlorine mixed with hydrogen took place on pulp and paper plant in Arkhangelsk. More than 50 tons of liquid chlorine exploded.
The incident occurred in a catalytic reforming unit. At 13:41, a leak occurred at the 90° elbow of a pressure pipe containing a mixture of hydrogen and naphtha. This pipe was located between the pre…

The incident occurred at a facility performing material tensile tests in hydrogen at cryogenic temperatures. At the end of the test, the cryostat top was removed. In order to increase vaporization…

A liquid hydrogen system exploded and burned during fill operations due to inadequate purging after the previous operation. [Ordin, NASA (1974)]

The balloon had a 3. 5m external diameter envelope made of anti-tear fabric (same techniques used in full sized balloons of the same company). The inner balloon was a meteorological balloon made of…
The accident happened in an anhydrous ammonia plant, commissioned in March 1977. Hydrogen accumulated inside a Benfield solution (hot potassium) storage tank and was ignited by a static charge, which…