HIAD Facility - Location Type: Unknown


The incident affected the raw material buffer tank (design pressure 0. 38 MPa) of a diesel hydrogenation unit in a refinery. This buffer tank is located between the hydrogenation reactor and the raw…
An explosion and a fire occurred at at a hydro-treatment unit of a chemical plant for lubricants. Plant own emergency response team was activated, assisted from local fire and emergency Services and…
The explosion occurred in the compressors unit of the plant. Witnesses reported a cloud of yellow smoke and a fire ball at its bottom. This first event was followed by a fire fed by a hydrogen pipe…
The incident occurred in the hydrogenation unit of a non-further specified chemical plant (SEVESO facility). The hydrogenation unit was probably part of the phenols processing. Before the occurring…
The accident occurred in the organo-metallic compound production unit, on a transport container for aluminium alkyls, which exploded during a cleansing process at the washing station. The incident…
At the time of the incident, the desulphurisation unit was shut down for scheduled cleaning of a cooling tower with reintroduction of a gas mixture into the system at a high hydrogen content. The…
The event occurred at an ethylene production plant. The plant was shutdown at the time as the supply of compressed air to the gauges had inadvertently been switched off. This failure of the air…
The incident at a bio-fuels research laboratory occurred when a visiting research fellow was transferring hydrogen, oxygen and carbon dioxide from compressed gas cylinders into a low-pressure mixing…

[Note of the event validator: according to the sources, hydrogen as combustible gas does not seems to have plaid part in this incident. However, it is more plausible that hydrogen, as the main…

This incident occurred at a chlorine production plant. A number of minor explosions occurred in the interrupter pot on a chlorine cell of the electrolyser. No injuries or damage were reported. No…
An explosion at a coal plant occurred as a steam methane reformer was being reactivated.
The naphtha and hydrogen gas leaked out from the gasoline reformer at the Southwest Petroleum as the relief-valve was operated after its repair. Although the source (Asian database ADRC) does not…
On a cold morning, the gasoil hydro-treatment unit was being brought back on line after being out of service to repair a governor problem on the recycle gas compressor. Several upset trips had…
An explosion occurred in a hydrocracking reactor fitted with TOC which is a automatic cut-off system for raw oil and hydrogen supply. On the day of the incident, the operation was stopped with TOC…
A reactor of a wide-range hydrocracking unit being operated by computer at 2500 psi (170 bar) failed explosively due to localised heating. Resulting explosion caused injuries and widespread damage to…
Five workers were in the process of trouble shooting a hydrogen compressor. No actual work was in process, but the compressor had still hydrogen in the lines. The three were only listening for…
Two employees were working on a electric furnace under hydrogen atmosphere that had jammed. The furnace exploded. The employees sustained flash burns to their faces and were taken to the hospital,…
A contained explosion in a hydrogen tank occurred at the thermal generation plant

An explosion occurred in a hydrogen storage tank followed by fire.

Employee #1, a maintenance worker, was killed by a hydrogen blast while working inside a batch hydrogenation unit.