This event occurred at the hydrogen 70 MPa dispenser of a refuelling station during the testing phase. Just after the start of the refuelling test, at a pressure of approximately 13 MPa, the…
The incident occurred at a dispenser of a hydrogen refuelling station (HRS). The HRS employee had just terminated the filling of a fuel cell vehicle (FHV) and was depressurising the filling hose,…
A compressed hydrogen container was being filled at a refuelling station. The container was belonging to trailer and consisted in a bundle of tubes connected via piping to a manifold and filling…
This incident occurred at the storage system of a hydrogen refuelling station during an inspection. The inspection consisted in the visual inspection of individual pressure vessels of the storage…
A fire occurred at a hydrogen refuelling station for buses. The incident was initially reported as an explosion due to a loud noise and vibrations felt in nearby buildings. However, subsequent…
A hydrogen leak in the hydrogen compressor unit of a filling station ignited causing the shut down of the whole station. The loss of containment was due the failure of a tie rod (diameter ~64mm) ,…
Hydrogen was accidentally released into the compressor room of a hydrogen refuelling station. The fixed gas detector in the compressor room issued a value of 48% vol. of he Low FLammability Level,…
This incident occurred at a 70MPa hydrogen refuelling station. After completing a filling test, the pressure in the filling hose suddenly dropped. A worker heard the hissing sound of a hydrogen…
A leak occurred at a dispenser hose of a hydrogen refuelling station. On the day of the accident six FCVs had already been filled. Four minutes after the start of the filling of a seventh vehicle,…
The accident occurred during the filling of hydrogen into a fuel cell vehicle (FCV) at a hydrogen station. The gas detector in the dispenser detected a leak, and the equipment was shut down. A…
The accident occurred at a mobile hydrogen station during a fuelling test for a fuel cell vehicle. The day before, the gas detector in the dispenser detected a leak and the equipment was shut down…
The incident occurred when refuelling with hydrogen a fuel cell forklift. The hydrogen was provided by a mobile refuelling station. The filling of a second forklift of the day had just begun, when…