Hydrogen release at a public hydrogen refuelling station.
The station was storing 6,000 litres of liquid hydrogen in ten tanks. Rescue services were alerted and the station's activity is interrupted. The leak was stopped by closing the valves. According to the H2Tools report (see references), a vehicle fill had depleted the high-pressure hydrogen inventory. Consequently, the compressor turned on to refill the storage by compressing 4 bar (60 psig) hydrogen from a liquid hydrogen tank up to the 380 bar (5500 psig) compressed storage tank. After running about 2 hours, a crankshaft bearing started to fail. This allowed greater movement of the shaft, which led to a shaft seal leaking hydrogen. The compressor shut down on low suction pressure and then the system was shut down using the e-stop by the emergency responders.
Event Date
October 6, 2009
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
INITIATING cause was a deterioration of a component of a hydrogen compressor.