Cavitation in a compressor (402)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Cavitation in a compressor

A hydrogen compressor had a major malfunction resulting in serious cavitations, vibrations and dead heading of the 1st stage. The incident resulted in 5 of the 8 lower head bolts on the first stage to snap, oil losses and damage to the 1st stage diaphragms. No breaches of hydrogen or contamination took place. The situation was noticed if a remote log in when reviewing the compressor pressures. The system was safely shut down and followed up by an on site investigation an hour later.
Event Date
January 10, 2013
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The INITIATING CAUSE was likely the malfunctioning of a high-pressure component The most probable component culprit was the inlet valve used for top off filling. This valve may have leaked and allowed high pressure hydrogen into the inter-stage when it was not expected. This caused the 1st stage to dead head which likely lead to the bolts breaking, oil loss and further cavitation's high vibrations. The ROOT CAUSE was unknown.
Facility Information
Application Type
Application
HRS 35 Mpa
Specific Application Supply Chain Stage
Components Involved
Compressor
Storage/Process Medium
Actual Pressure
35
Design Pressure
35
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Post-event Summary

Compressor was repaired ad back in operation as of two weeks after.

Lessons Learned
The safety measures functioned as designed and the system was safely shut down, although with damages. However, the investigation was not able to full determine technical reasons and causes of the problem. Few changes were made and was decided to increase the attention to the operational history of the component, to be able to catch early sign of a possible re-occurrence of the problem.
Event Nature
Emergency Action
The system was shut down followed by an on site investigation an hour later.