Skip to main content

HIAD Event Initiating System: Hydrogen System Initiating Event


A fire occurred on top of a vent stack attached to a LH2 vessel. The ignition source was unknown but electrical storms in the vicinity may have been responsible. The flame was extinguished by…

A fire at the exit of the vent line occurred when filling a tube trailer. An employee suspected a flame at the outlet of the hydrogen venting line during the filling of a trailer. , by sawing the air…
Lightning caused fires at a plant near Hamburg after igniting a hydrogen mixture release through a ventilation pipe
The ignition of a hydrogen leak occurred at a semitrailer connected to a pressure reducing station, while waiting a transfer. The alert was given by personnel of the company cafeteria located nearby.…

This incident occurred at a at an electronics plant. While transferring of hydrogen from a compressed hydrogen tube trailer to stationary cylinder banks, a leak developed on the transfer hose and…

A LH2 trailer was delivering at a customer location. The LH2 transfer had just been terminated and the driver was ready to depressurise the trailer to remove the hose. When he started to open the…

During the preparation for a liquid hydrogen transfer from a tanker to a stationary storage system, the safety valve opened and the gas ignited. The incident occurred when a pressure build-up was…

This incident occurred at CVD (coating vapour deposition) equipment. During operation, a vacuum pump for air discharging was turned on and by mistake silane and hydrogen gases were allowed to flow…

This incident occurred during the delivery of a hydrogen gas container to a customer site. When a worker turned the protective cap of the container, the valve handle turned together with the…

Near the end of the process of filling a gaseous hydrogen tube trailer at a liquid hydrogen trans-filling station, a safety pressure-relief device (PRD) rupture disc on one of the tube trailers ten…

A compressed hydrogen tube trailer was fully loaded and parked in the sun. The heat caused a pressure build-up, so that a burst disc failed prematurely venting hydrogen, which ignited. 13,360 cu…

A compressed hydrogen tube trailer was fully loaded and parked, when a rupture disc on one of the tubes failed. The escaping hydrogen ignited. 9583 cu ft were released. [Zalosh and Short, 1978]…

The incident occurred at the site of a gas production company. During the filling of a compressed hydrogen trailer, an end plug thermal pressure relief device (TPRD) had an unplanned activation.…

A trailer carrying compressed hydrogen tubes took fire at the rear while parked at a warehouse. The trailer-truck was carrying 130,000 standard cubic feet of hydrogen (300 kg), and was parked back…

This incident occurred at a linear alkylbenzene manufacturing plant. It affected dehydrogenation reactor of normal paraffin, during the operation of catalyst exchange in the reactor. This is usually…

A hydrogen leak caused a fireball in in an industrial gas processing and conditioning plant. The leakage occurred at the end of a hose in the packaging station, consisting in filling of tanks…

During startup of the hydrodesulphurisation unit, diesel and hydrogen leaked from a flange near the heat exchanger. The flammable mixture ignited spontaneously, causing a fire. Plant personnel…

Hydrogen leakage occurred on a pipe flange in an ammonia synthesis unit. A fire started immediately, which was taken under a control before the arrival of firefighters.

The hydrogen fire occurred at a solvent manufacturing plant. Hydrogen leaked from a flange of a hydrogen supply pipe and ignited inside the thermal insulation around the pipe. This first fire was…

The incident occurred at a hydrogen storage unit serving a catalytic reformer. During transfer of hydrogen from the storage unit to the reformer, a flexible hose was over-pressurised and caught fire.…