HIAD Event Initiating System: Hydrogen System Initiating Event


A hydrogen gas leak at an oil refinery ignited
An explosion followed by a fire occurs in a refinery, originated by a hydrogen release at the hydrogen compressor.
Due to unsealing of flange connection in a heat exchanger, hydrogen leaked and ignited. At 20 m height, under pressure of 0,25 MPa.
This incident occurred at a reactor for the isomerization of wax in a lube oil plant. The high-pressure reactor ruptured during a catalyst activation operation. A hot (400 C) gaseous stream of…
A 24" pipe carrying synthesis gas (Hydrogen = 43. 5%, Nitrogen = 14. 08%, Methane = 0. 2%, Carbon Dioxide = 12. 3%, Water = 29. 3% by volume) ruptured. About 60 kg of hydrogen contained in the gas…
A fire broke out on a heat exchanger in a hydrocarbons plant. The cause of the fire was leakage of hydrogen.
Hydrogen was released into a diesel desulfurization unit, producing a 50-meter-long horizontal torch flame upon ignition. The unit was operating normally. Refinery firefighters responded quickly and…
Follow a leak in a seal of a heat exchanger (metal-covered asbestos) a fire occurred in a reforming process. The hydrogen-rich mixture caused spontaneous inflammation. The fire lasted 30 minutes. The…
Firefighters used thermal imaging cameras to locate and extinguish a hydrogen fire at a silicon manufacturing plant.
The accident happened in a refinery unit, constructed ten years before. A pigtail ruptured in a steam reformer for the production of hydrogen, and caused a major fire, which destroyed most of the…
Due to the failure of a exhaust system, compressed hydrogen leaked into an area containing electrical components, with consequent fire. Leakage was allowed when exhaust system failed.
A fire was sparked by a hydrogen leak at a company producing composites for aerospace applications. The fire started in a pipe bringing hydrogen to the oven. It ignited likely from just the friction…
The accident took place in a tank-type pressurised separator on the synthesis gas line of an ammonia production plant. The pressurised separator operates at nominal values of 25 bar and 5°C. It…
In a fertiliser plant, an ammonia synthesis unit stopped following the malfunction of an alternator due to a thunderstorm. The safety features were operating normally, yet the synthesis gas (N2 / H2)…
The fire was in a polyamide production chemical plant classified SEVESO During maintenance of an isolated unit producing a polyamide monomer (LACTAME), a fire developed on the ground floor of the…
A fire occurred at the desulphurisation unit of a refinery during maintenance work. On the day of the incident, a distillation unit was shutdown for a steam air tightness test. A leak was found at…
The accident occurred in the de-sulphurisation unit, and specifically on a pipeline at 50 bar, for the recycling of the hydrogen (containing hydrogen sulphide impurities). The pipe failed due to…
The event occurred at the charge heater (also called a 'fired heater') of a vertical cylindrical hydrodesulphurisation reactor. The heater lost hydrogen flow briefly while the unit was being changed…
In a hydro-desulphurisation unit of a refinery, a leak on a hydrogen line ignited and damaged the surrounding lines, including one with acid gas. The weather conditions (fog and very little wind)…
A hydrogen skid was placed into service in a nuclear power plant, outside the controlled area. This skid, like seven others, was located in a gas cylinder storage facility. It was supplied by several…