Skip to main content

HIAD Event Initiating System: Hydrogen System Initiating Event


A hydrogen leak occurred in in the cooling system of electricity generation part of the in a nuclear power plant. .
It was a small incident in a heat-electric power plant. The alarm was registered at 11:26 and the fire was extinguished at 12:03. The incident took place during tests using the reserve power…
A hydrogen leak occurred on the a coolant pipe of an electrical generator located in the turbine building, at 200 m from the reactor. Because of the welding works ongoing at that moment on the pipe,…

The explosion occurred at a hydrogen drier used for the treatment of the hydrogen used as coolant in a power generator. The hydrogen leaked, entered the contactor panel box of the drier and was…

This incident occurred in the turbine compressor system. A severe hydrogen ingress into the stator coolant system resulted in a fire in the stator coolant head tank (ignition source unknown). No…

A leak of a compression fitting lead to the build up of an explosive air/hydrogen mixture in the generator pit. The ignition of the mixture was caused by corona discharge. The resultant explosion…

The compressor-turbine unit tripped while on on-load, due to a serious fire between alternator and one of the bearing. The failure of a generator slip ring and of the hydrogen seal caused the leak of…
Explosion of hydrogen at slip ring end of an alternator. It was caused by a hose fracture within the generator casing, which led to a discharge of water into the casing and subsequent electrical…
A nuclear Power Plant experienced a main generator hydrogen fire. Although a senior reactor operator (SRO) and auxiliary operators from another shift were available immediately, the need to provide…
This incident occurred during maintenance works after an outage at a turbine and generator unit of the plant. At the time of the incident, 15 maintenance technicians had already been working on the…
The incident started at the unit removing CO2 from the process gas stream of a hydrocracking facility. (Catalysed Removal of Carbon Dioxide = Catacarb). Localized corrosion caused a pipe to fail and…
A sudden fire started at the hydrogen compressor of a refinery's hydrocracking unit.

The event occurred at a plant for the production of ethylene, and affected the unit for the hydrogenation of pyrolysis gasoline. During a shutdown operation of the hydrogenation plant, the…

This incident occurred at a unit designed to convert heavy oil residues into refined products. It involved a fluidized bed reactor and the related hydrogen supply system serving the optimisation…

A fire occurred in a hydrogen and catalyst loading lines of heavy oil unit. The most likely cause was that a hydrogen purge pipeline failed allowing hydrogen to escape. This mixed with hot oil…
A hydrogen leak occurred from a low temperature valve on an acetic acid plant. The leak ignited and the resulting fire burned for about an hour. There was considerable media attention, particularly…
The incident occurred at the direct desulfurization unit of heavy oil. A 130×90 mm oval opening occurred in the bypass pipe of the hydrogen sulphide absorption tower for the circulating gas, at a…
The explosion occurred during preparatory work to start a compressor that supplies hydrogen gas to a heavy oil direct desulfurization unit. The inspection cover of the crank case came off, injuring…

This incident occurred at the storage system of a hydrogen refuelling station during an inspection. The inspection consisted in the visual inspection of individual pressure vessels of the storage…

At a nuclear power plant, a fire occurred in the station's hydrogen storage facility while the plant was operating at 100% power. The fire was reported to the control room by a non-licensed operator…