Skip to main content

Fire at a generator of a power plant (281)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Fire at a generator of a power plant

Explosion of hydrogen at slip ring end of an alternator. It was caused by a hose fracture within the generator casing, which led to a discharge of water into the casing and subsequent electrical flashover. Pressure pulse blew out the hydrogen seals and resulted in a fire in the turbine hall.
Event Date
March 8, 1983
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
INITIAL CAUSE: a hose failure. ignition. ROOT CAUSE unknown.
Facility Information
Application Type
Application
unspecified type of power plant
Specific Application Supply Chain Stage
Components Involved
generator cooling system.
Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Event description provided by HSE, original source confidential