Skip to main content

HIAD Causes: Human Factors


The incident occurred on a laser cutting system, and affected the top of a water storage tank. The water was used to cool the cutting part. The plant is mainly dedicated to steel cutting, but the…

The laboratory works with soil bacteria that cannot survive in the presence of oxygen. As a result, research work is conducted inside a plastic chamber in which the chemical constituents in the air…
This entry reports only the role of hydrogen in this nuclear accident. For a short description of the initial causes and the incident evolution, see "pre-event summary” and for a much more detailed…
A gas release occurred in the building containing the compressors for the recirculation of process gas of a plant producing fertilisers. The process gas was a mixture of hydrogen and nitrogen. It…
Explosion in a fine organic chemical plant (Seveso classified ) The event occurred during the cleaning of a reactor. At the completion of a batch manufacturing of a soft reducing agent, an operator…
This accident took place in different phases and in two different units of a refinery:It consists first in a non-hydrogen accident, followed by a hydrogen-related accident. Before the hydrogen…
During the polymerization of ethylene in a 750 litres pressurized reactor, an exothermic runaway decomposition occurred and ethylene and its decomposition products were released through the two…
The explosion was caused by the ignition of hydrogen during reaction with sodium metal. The Chemistry Department routinely dried solvents using metallic sodium. This leaves an excess of sodium metal,…
An explosion occurred whole two employees inside a facility were working with aluminium paste. Crews believed the blast was caused by hydrogen that had built up in the plant.
The event occurred during welding works which ignited accidentally released hydrogen. The plant had been partially shut down for repairing works to a pipe affected by internal cracks. The repairing…
Explosion in an electrolyser producing chlorineThe explosion occurred after the opening of an auxiliary circuit-breaker. The opening of the auxiliary circuit breaker trigger the shut down of the…
An explosion occurred in an electrostatic precipitator whilst it was being accessed for maintenance. The explosion caused an inspection hatch cover, which had been unbolted, to be blown off and…
Works at the power grid of a hydrogen production unit is at the origin of the sequence of the following events: 1. Fusion of a safe fuse triggering the closure of a valve on the manifold of a pistons…
Five barrels of aluminium dust that had been removed from an outdoor dust collector were sealed and stored in the plant adjacent to electrical panels. One of them had somehow been contaminated with…
At an agrochemical plant, an explosion occurred near a drained hydrofluoric acid tank, when 4 employees were welding on adjacent pipelines. An investigation was launched to determine this accident’s…
An explosion occurred in the teat treatment workshop of this site. The explosion was centred in the electrical control panel of the High Velocity Oxy Fuel (HVOF) thermal spraying equipment. The…
The Microbiological Anaerobic Chamber of approximately 2 m3 capacity was containing an explosive mixture of hydrogen and air. A fire followed the explosion, but was rapidly extinguished by staff…

The incident occurred at a facility performing material tensile tests in hydrogen at cryogenic temperatures. At the end of the test, the cryostat top was removed. In order to increase vaporization…

A tank "filled with low-pressure hydrogen" exploded at a food manufacturing plant, killing three workers. The accident occurred when the workers were welding inside the tank after clearing hydrogen…

an explosion occurred in a hydrogen storage tank at the hydrogen station of the oxygen plant of the energy centre. The 10 m3 hydrogen storage tank at the hydrogen station belonging to the oxygen…