Explosion in a laser cutting plant
The incident occurred on a laser cutting system, and affected the top of a water storage tank. The water was used to cool the cutting part. The plant is mainly dedicated to steel cutting, but the specific system affected by the explosion was cutting aluminium. The process produces hydrogen which recirculate with the water. On the day of the incident, workers decided to weld a new throughput in the tank, but as soon as the melting arc was switched on, the hydrogen ignited and exploded injuring three workers and propelling the small welding set through the roof of the unit.
Event Date
November 19, 1999
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences

The INITIATING cause was the accumulation of hydrogen accidentally produced from water when laser-cutting aluminium. The existing national guidelines for laser cutters mention the possibility of hydrogen formation by cutting aluminium, but apparently this had not been taken in consideration in the case of the affected plant. This could be seen as lack of risk assessment or of effective instructions & procedures.