The drivers failed to stabilise the tank pressure after having delivered the liquid hydrogen. Therefore they had to stop and perform a manual vent on journey back to the base. [Zalosh and Short,…

Before loading it with liquid hydrogen, the cyrogenic tank had been purged with nitrogen for maintenance work. After the loading, the drivers failed to stabilise the internal pressure of the tank,…

The pressure building valve opened due to vibration from the road, causing the build-up of the internal pressure. The drivers performed a hydrogen venting and re-sealed the valve. [Zalosh and…

A pressure build-up in the tank of a liquid hyrogen tanker caused the drivers to vent 6000 cu ft of hydrogen to reduce the pressure. [Zalosh and Short, 1978]

Pressure buildup in tank was manually vented by driver releasing 1000 cu ft [Zalosh and Short, 1978]

The tank of a liquid hydrogen tanker was manually vented prematurely on its empty return trip. 9,000 cu ft werereleased [Zalosh and Short, 1978]

While returning to the base, a liquid hydrogen tanker had to be vented twice. The cause of the overpressure was a malfunctioning scale which allowed a slight overload of hydrogen. [Zalosh and…

Motorway accident which involved a large quantity of vehicles and a gaseous tube trailer which transported gas hydrogen in pressure. Some cars were burning under the back part of the gaseous tube…

At an off-site LH2 fill station, a LH2 trailer hit the GH2 purge shut-off valve handle. The tubing attached to the purge valve was bent on both ends but did not leak. [Ordin, NASA (1974)]

An LH2 trailer-tractor was returning to the base after a hydrogen delivery at a customer. The trailer was almost empty. Nevertheless, the drivers noticed an increase in the trailer internal…

An LH2 trailer-tractor was returning to the base after a hydrogen delivery at a customer. The trailer was almost empty. Nevertheless, the drivers noticed an increase in the trailer internal…

An LH2 trailer had just delivered hydrogen to a customer. The vehicle exited the plant, weighted the trailer parked to get the weight receipt. While in the building, a safety device activated due…

A LH2 trailer had delivered hydrogen to a customer and on the way was heading back to base, when the tank pressure rose from 40 psi to 128 psi. The drivers stopped at a truck parking place and…

A LH2 trailer was traveling to delivery hydrogen to a customer, while the drivers noticed an increase in trailer pressure. To avoid the possibility of having the safety vent open while on the road…

A LH2 trailer/truck had delivered liquid hydrogen to a customer site and was travelling back empty to the base. The drivers noticed an increase in trailer pressure. To avoid the possibility of…

A LH2 trailer had just delivered hydrogen to a customer and was travelling on a highway returning to the base, when the driver noticed that the pressure inside the tank was increasing rapidly. The…

A full liquid hydrogen tanker was travelling from the home terminal to deliver to a customer, when the drivers noticed a pressure rise during a safety check. The drivers called in and were…

An empty liquid Hydrogen tanker was returning to the base terminal from a delivery at a space centre. At the departure, the internal vessel pressure was 8 psig. At the first safety check, the…

A liquid hydrogen tanker was loaded at the home base and dispatched to a customer (approximately 790 km). The internal vessel pressure after filling was 8 psig (1. 4 bara). During transit, the…

A liquid hydrogen tanker was travelling from the home terminal to delivery to a customer. After approximately 7 hours and 400 miles, the drivers noticed hydrogen venting from the vent stack. They…