The fire broke out in the acid etching tank of the ferric chloride manufacturing unit of a SEVESO-classified chemical plant. In this tank, the attack reaction of the iron metal with hydrochloric acid…
Hydrogen fire at a chlorine chemical production plant (Seveso-classified) Hydrogen ignited in a chlorine electrolyser unit. The facility was shutdown when the incident occured. The staff of the unit,…
A leak occurred while loading a trailer carrying hydrogen gas cylinders. The trailer was loaded with 4 bundles of 60 cylinders at 200 bar which were beeing refilled. The leak was heard, and an…
The incident occurred outside a fuel cells manufacturing facility. While preparing for transfer of liquid hydrogen from tanker truck to a stationary storage tank, a release of hydrogen occurred,…
A lorry loaded with gaseous hydrogen cylinders caught fire and shut a motorway. No one has been injured.

The incident occurred at a hydrogenation reactor producing alcohols. At the time of the fault, the plant was in normal operation. A sudden leak of hydrogen occurred on the flange of the upper…

A hydrogen leak occurred on the hydrogen line of a hydro-desulphurisation unit, followed by ignition . The failure was located on a supply manifold of the unit at a support beam. The unit was shut…
Hydrogen leaked from an analyser of a unit for the production of sodium chlorate. Thehydrogen ignited. On-site staff isolate the leak very quickly, so that the amount of hydrogen released was…
Three workers were working in the sulphur recovery unit (SRU), trying to restore the hydrogen flow. The workers were trying to isolate the cause of a flow problem: hydrogen was entering the…
A fire was caused by a hydrogen leak and led to the formation of a fireball at the end of a hose at the conditioning station. It occurred while transferring hydrogen from a stationary storage to he…
The regular maintenance of the hydrogen production equipment had been completed and the plant was about to start up. At this point, fluid mainly composed of hydrogen was sent via a pipe to the…
The fire occurred around 13:20 on three cells of the chlorine manufacturing unit. A leak of hydrogen in the electrolysis room was at the origin of the fire; the ignition of the H2 cloud caused a…
The fire occurred on a flange of a hydrogen supply line to a desulfurization reactor unit of diesel, which leaked and ignited (30 cm flame) The leak was stopped by isolating the part of line affected…
A hot oil line (8-inch) in the hydro-desulphurisation (HDS) unit failed due to fatigue cracking. Hot oil at 50 bar and 343°C sprayed across the roadway into the hydrogen units where ignition occurred…

A hydrogen fire broke out at the aft end of the orbiter connected to the LH2 onboard tank of a space shuttle. This happened during the abortion of the launch, occurred due to another cause, the…

In a metal production company, a leak occurred on valve of a hydrogen line. A new valve was ordered. Almost one month later workers arrived on site to replace the valve. After one hour they heard an…
The event occurred in a desulphurisation unit for heavy oil (hydro-cracking, Isomax process). The hydrogen released from one of the heat exchangers where the feed gases are pre-heated by the reactor…
An explosion took place at the hydrodesulphurisation unit of a refinery's crude oil. A leak occurred on suction line of a hydrogen compressor used for the re-circulation of the hydrogen required for…
A fire broke out on the world’s first hydrogen carrier vessel shortly before setting sail from Australia to Japan carrying the world’s first international shipment of liquefied hydrogen. A flame was…
Hydrogen leaked and ignited on a cell in the sodium chlorate (NaClO3) workshop of a chlorinated products plant. There were no victims and no damage to the environment. On-site firefighters controlled…