Skip to main content

HIAD Nature Event - Ignition Source: Unknown


Firefighters used thermal imaging cameras to locate and extinguish a hydrogen fire at a silicon manufacturing plant.
A short circuit occurred in a bus bar system in a transformer building, causing a fire in adjacent switches. This was followed by the tripping out of the three refinery turbo-alternators, cutting off…
The accident took place in a tank-type pressurised separator on the synthesis gas line of an ammonia production plant. The pressurised separator operates at nominal values of 25 bar and 5°C. It…
The accident occurred on the hopper fine powders from a pair of cyclones (the hopper is the bottom conical part of the cyclone collecting the powder/dust separated from gas phase). A bursting disc…
The fire was in a polyamide production chemical plant classified SEVESO During maintenance of an isolated unit producing a polyamide monomer (LACTAME), a fire developed on the ground floor of the…
A fire broke out at a flange inside a heat exchanger of the catalytic reforming unit of a refinery. This heat exchanger had the purpose to pre-heat the load of heavy oil and hydrogen by recovering…
The accident occurred in the de-sulphurisation unit, and specifically on a pipeline at 50 bar, for the recycling of the hydrogen (containing hydrogen sulphide impurities). The pipe failed due to…
In a hydro-desulphurisation unit of a refinery, a leak on a hydrogen line ignited and damaged the surrounding lines, including one with acid gas. The weather conditions (fog and very little wind)…
An explosion occurred inside the hydrogen washing tower of a chlorine production plant. The explosion was preceded by an abrupt reduction in the electrolysis flow due to a rectifier malfunction. The…
A fire started on the primary hydrogenation reactor of a chemical plant synthesizing alcohols and acids by reactions between olefins and a H2 / CO gas mixtures. The alcohols are synthesised in 3…
The event occurred on vent stack of an ammonia synthesis unit. The release of the gas was more specifically on the water purge line or the hydraulic guard of the vent stack. The process gas…
Release of gas from a coking plant on a gas holder which ignited causing a fire. The accident took place during repair works. The gas was made of 65 % of hydrogen , 25 % of methane , 4. 1 % of carbon…
A trailer-tractor transporting hydrogen cylinders veered off the road to the right at around for unclear reasons and eventually tipped over to the left. Part of the 4,000 cubic meters of hydrogen…

A truck loaded with 400 hydrogen bottles crashed into a concrete barrier and tipped over. After tipping over, the vehicle slid about 150 meters across the road. The hydrogen was released, ignited…

While driving on a highway, the driver of a CGH2 tube trailer was notified by another driver of the smoke coming from his trailer. The CGH2 tube trailer parked in a place considered safe,…

A release of compressed hydrogen and subsequent fire occurred during the transportation of a CGH2 trailer by means of a truck tractor. The tube trailer module contained 25 fully wrapped carbon filler…

Safety slug in the vent pipe of a hydrogen trailer failed, damaging the pipe and causing a hydrogen leak. The following fire damaged several other trailers. [Zalosh and Short, 1978]

A fire developed at a recycle gas compressor of a refinery. During recommissioning, the compressor, belonging to a hydro-treatement unit, was overpressurised. The cylinder head was blown off,…

In a hydro-desulphurisation unit of a refinery, an operator which was performing a control tour heard noises and clicks on the hydrogen compressor and stopped it. The compressor was of a…

A hydrogen fire occurred at a hydrogen refuelling station (HRS). The HRS hydrogen storage consisted of two trailers at 200 bar, both connected via flexible hoses to the station delivery system…