Skip to main content

HIAD Nature Event - Flame Type: Jet flame


A fire started on the primary hydrogenation reactor of a chemical plant synthesizing alcohols and acids by reactions between olefins and a H2 / CO gas mixtures. The alcohols are synthesised in 3…
A release of compressed hydrogen and subsequent fire occurred during the transportation of a CGH2 trailer by means of a truck tractor. The tube trailer module contained 25 fully wrapped carbon filler…
A compressed hydrogen trailer released accidentally hydrogen which ignited producing a hissing 60 jet flame. It triggered the evacuation of a one-mile stretch. It was estimated that the tanker burned…
While filling a 9 litre gas cylinder with pressurised hydrogen in the hydrogen storage area, a blast occurred which destroyed the low pressure gauge, followed by a jet fire which damaged the surface…
A fire broke out affecting the heavy fuel purification plant of the refinery. The incident could have originated by the failure of one of the following plant components: - pipes leading to the…
The incident occurred at the hydrocracker unit, which was being shut down for maintenance and the reactor was in a hydrogen purge cycle. A hydrogen gas line failed at a weld. The line was at 3000 psi…
The fire occurred after a hydrogen released from a venting valve opened for inspection. The hydrogen was at 300 bar and 300C centigrade and between 200 and 300 bar. The hydrogen ignited probably…
A hydrogen jet fire occurred on a 25m3 tank while transferring a catalyst to a buffer tank. The constabulary created an area of safety around the plant while the staff extinguishes the fire by…
A hydrogen jet fire from a pipe was detected by a night operator making rounds in a solvent production unit. The unit's emergency response team managed the fire in minutes. Operators stopped the flow…
The fire occurred on a flange of a hydrogen supply line to a desulfurization reactor unit of diesel, which leaked and ignited (30 cm flame) The leak was stopped by isolating the part of line affected…
A hot oil line (8-inch) in the hydro-desulphurisation (HDS) unit failed due to fatigue cracking. Hot oil at 50 bar and 343°C sprayed across the roadway into the hydrogen units where ignition occurred…
A hose of a hydrogen tanker parked in at a specialised company ruptured. The released hydrogen ignited and exploded, followed by a fire probably fed by the continuously leaking hydrogen. The local…
The event occurred in a university research building dedicated to the study of the take-off of space launchers . An operator gave the alarm during the hydrogen pressure pre-setting phase. he had seen…
A truck transporting a pallet of 30 compressed hydrogen cylinders was traveling on a highway when gas started leaking from the welded pipe. The fire department ordered the hydrogen in to be released…
A tractor - semitrailer with horizontally mounted cylinders filled with compressed hydrogen struck a northbound pickup truck that had veered in front of it. The tractor-semitrailer then lost control…
A pressure relief device (frangible burst disc) on one of a 26 tubes on a tube trailers failed prematurely and released hydrogen while filling a hydrogen storage tank at a government facility. The…
The release occurred in the hydrogen storage system of a refuelling station. In the night a leakage occurred at one of the 120 high pressure bottles (800 bar). The leakage occurred at a screwed…
The leak occurred at the ammonia reactor after a technical shutdown of 4 days. When the production was resumed and the syngas compressor restarted 14 hours later, a jet-fire occurred. The Internal…