Skip to main content

HIAD Nature of the Consequences: Explosion


[Note of HIAD event validator: The event description relates to a real accident, the details of which however are not publicly available. The descriptors are based on the analysis provided by the…

Explosion in an electrolyser producing chlorineThe explosion occurred after the opening of an auxiliary circuit-breaker. The opening of the auxiliary circuit breaker trigger the shut down of the…
The explosion occurred in a copper electroplating plant test furnace when starting the operation of copper plating. A tinned copper pipe had been placed inside another copper pipe and lined with…
An explosion occurred in an electrostatic precipitator whilst it was being accessed for maintenance. The explosion caused an inspection hatch cover, which had been unbolted, to be blown off and…
In the acid treatment room of a Seveso low-threshold hazardous waste treatment centre, an explosion occurred on a 250 m³ concrete tank containing acid sludge being neutralized. The explosion occurred…
The explosion occurred in an incinerator for non-industrial wastes, during inspection and repair works. These were due to a large quantity of aluminium which produced a solid lump of ash. The…
Works at the power grid of a hydrogen production unit is at the origin of the sequence of the following events: 1. Fusion of a safe fuse triggering the closure of a valve on the manifold of a pistons…
Five barrels of aluminium dust that had been removed from an outdoor dust collector were sealed and stored in the plant adjacent to electrical panels. One of them had somehow been contaminated with…
In this plant, after conversion of the major part of the carbon dioxide into urea, the off-gasses from the reactor consist of ammonia, carbon dioxide, hydrogen, oxygen and nitrogen. Prior to venting…
At an agrochemical plant, an explosion occurred near a drained hydrofluoric acid tank, when 4 employees were welding on adjacent pipelines. An investigation was launched to determine this accident’s…
An explosion occurred in the teat treatment workshop of this site. The explosion was centred in the electrical control panel of the High Velocity Oxy Fuel (HVOF) thermal spraying equipment. The…
In a chlorine manufacturing unit, an explosion occurs in the room of the electrolysis cells. The accident occurs during the start-up phase of the unit, it is due to the presence of hydrogen in the…

An explosion occurred in an industrial cleaner, blowing off and shattering the cover from the top of the machine. It is believed that the explosion was caused by accidental formation of hydrogen…

During a test in which GH2 was driving gas, an explosion occurred in the test section. The drive chamber was over-pressurized to 3500 psi (240 bar). The test section failed; windows designed for a…

Fire in bulk hydrogen storage compound. Pressure gauge shut off valve spindle blown out (could be completely unscrewed and removed). The subsequent leak ignited by unknown source. No injuries…
The incident occurred at a caustic soda electrolysis plant. A chlorine suction pump failed on a sodium hydroxide electrolysis unit. The arrest of the pump caused the stop of the electrolysis current.…

A fuel cells and hydrogen city bus was refuelling at a hydrogen refilling station. It had just terminated this operation and the engine was restarted, that an explosion occurred at the back of the…

In a graphite purification workshop, the cooling circuit of an electric furnace leaks, the water decomposes in contact with materials heated to a temperature of 1,800°C; the gas mixture (hydrogen,…
Explosion in a chemical manufacturing plant for the pharmaceutical and cosmetics industries, classified as Seveso high level,The explosion occurred in the hydrogenation reactor, when opening two…
Explosion in a food products plant (Seveso classified) The event occurred in the settling cyclone of a hydrogenation reactor of a starch production unit. The process consisted in introducing the…