HIAD Facility - Storage Medium: Gas


The event occurred at the flanges on the outlet of a desulphurization reactor, which was working under about 300 degrees C. The flanges and bolts were cooled down by a large amount of rainwater which…
A fire started in a refinery's gas oil desulphurization unit. The purpose of this unit is to separate sulphur from hydrocarbons and to do so, the latter are raised to 340°C in the presence of…
A jet flame occurred in a diesel distillation unit. It was caused by the release and ignition of hydrogen from the low-pressure (60 bar) section of a the unit. It occurred during maintenance works…
the fire was detected by an employee during the normal inspection tour. It was caused by the ignition of a leak of process gas (hydrogen, methane and water vapour) from the reforming furnaces. The…
A gas leakage (approximately 70% hydrogen, 21% nitrogen and the rest carbon monoxide and other impurities) occurred at the connection between a temperature measurement casing and a flange in the…
A jet fire occurred on the ammonia production unit, caused by a leak on a hydrogen pipe. Hearing a strange noise, an employee triggered the alarm after having discovered an ignited jet of hydrogen.…

An explosion of a mixture of hydrogen and hydrocarbons occurred at a fired heater of an ethylene unit of a chemical plant. The bad weather caused the shut down of the boiler units. This shutdown…

An explosion of a mixture of hydrogen and hydrocarbons occurred at a fired heater of a refinery. A mixture of a hydrogen and hydrocarbon mixture was accidentally released into the firebox of a…

Leak from faulty hydrogen seal ignited by short circuit between inboard slip ring and outboard slip ring radial lead connection. Hydrogen flame caused damage to brush gear assembly and inboard slip…
An isolation failure in starter coil of the high voltage generator induced an electric arc to the hydrogen supply line, with consequent fire and melting of the line. [Zalosh and Short, 1978]
The fire was the consequence of the malfunctioning of a hydrogen compressor. This compressor was used to supply hydrogen to a reactor unit amining at increasing gasoline octane values.
A leak occurred on a 4 inch hydrogen main gas line which ran along a pipe bridge at the east end of a first stage compression plant building. The relased hydrogen ignited. The source of ignition was…

The fire developed in a hydrogen production plant serving an food manufacturer. A high-pressure compressor line (non-further specified) ruptured. It was impossible to use isolation valves to limit…

A hydrogen leak in the hydrogen compressor unit of a filling station ignited causing the shut down of the whole station. The loss of containment was due the failure of a tie rod (diameter ~64mm) ,…

Employees were refilling a rack of 15 hydrogen cylinders that were connected together on a steel pallet with railings. A leak developed at a valve and the pressurized hydrogen ignited. Operations…
The incident took place on the reforming furnace unit of the plant. Around 23:30 pm, during a normal inspection tour, an operator detected a fire on a section of a steam line. The operator…
A fire in a leaking hydrogen unit at a 220,000-barrel oil sands plant temporarily cut production nearly 80 percent.
The accident occurred in a plant producing synthesised active ingredients for the pharmaceutical industry. An explosion and a fire occurred in one of the workshops of the plant. The chemical reaction…
The hydrogen release of a defect valve on the hydrogen supply line ignited due to an unknown cause. The fire caused the melting of soldered joint with consequence additional release of hydrogen at 6.…
Fire on a filter of an autoclave. The event occurred in a plant for the production of plastics. After catalytic synthesis of amines, the filter of the autoclave was taken out for cleaning. During the…