Skip to main content

HIAD Facility - Storage Medium: Gas


In a fertiliser plant, an ammonia synthesis unit stopped following the malfunction of an alternator due to a thunderstorm. The safety features were operating normally, yet the synthesis gas (N2 / H2)…
The fire was in a polyamide production chemical plant classified SEVESO During maintenance of an isolated unit producing a polyamide monomer (LACTAME), a fire developed on the ground floor of the…
A fire broke out at a flange inside a heat exchanger of the catalytic reforming unit of a refinery. This heat exchanger had the purpose to pre-heat the load of heavy oil and hydrogen by recovering…
The accident occurred in the de-sulphurisation unit, and specifically on a pipeline at 50 bar, for the recycling of the hydrogen (containing hydrogen sulphide impurities). The pipe failed due to…
The event occurred at the charge heater (also called a 'fired heater') of a vertical cylindrical hydrodesulphurisation reactor. The heater lost hydrogen flow briefly while the unit was being changed…
In a hydro-desulphurisation unit of a refinery, a leak on a hydrogen line ignited and damaged the surrounding lines, including one with acid gas. The weather conditions (fog and very little wind)…
A hydrogen skid was placed into service in a nuclear power plant, outside the controlled area. This skid, like seven others, was located in a gas cylinder storage facility. It was supplied by several…
An explosion occurred inside the hydrogen washing tower of a chlorine production plant. The explosion was preceded by an abrupt reduction in the electrolysis flow due to a rectifier malfunction. The…
A fire started on the primary hydrogenation reactor of a chemical plant synthesizing alcohols and acids by reactions between olefins and a H2 / CO gas mixtures. The alcohols are synthesised in 3…
The event occurred on vent stack of an ammonia synthesis unit. The release of the gas was more specifically on the water purge line or the hydraulic guard of the vent stack. The process gas…
The fire occurred on the tube plate gaskets of 3 of the 4 exchangers loaded with catalytic reforming effluent. The fuel (500°C and p=30 bar) was a mixture of 30% hydrocarbons and 70% hydrogen. After…
Release of gas from a coking plant on a gas holder which ignited causing a fire. The accident took place during repair works. The gas was made of 65 % of hydrogen , 25 % of methane , 4. 1 % of carbon…
As the airship approached the docking mast, it performed a sharp turn to face into the wind, which was shifting. The engines were run at full speed astern for about a minute to slow the airship. Dust…
The fire developed on a hydrogen bus during filling, and was detected due to the development of smoke and a smell of burned materials. The power cable of the compressor had overheated. Two are the…
A trailer-tractor transporting hydrogen cylinders veered off the road to the right at around for unclear reasons and eventually tipped over to the left. Part of the 4,000 cubic meters of hydrogen…

A truck loaded with 400 hydrogen bottles crashed into a concrete barrier and tipped over. After tipping over, the vehicle slid about 150 meters across the road. The hydrogen was released, ignited…

Near the end of the process of filling a gaseous hydrogen tube trailer at a liquid hydrogen trans-filling station, a safety pressure-relief device (PRD) rupture disc on one of the tube trailer’s…

While driving on a highway, the driver of a CGH2 tube trailer was notified by another driver of the smoke coming from his trailer. The CGH2 tube trailer parked in a place considered safe,…

A release of compressed hydrogen and subsequent fire occurred during the transportation of a CGH2 trailer by means of a truck tractor. The tube trailer module contained 25 fully wrapped carbon filler…

Safety slug in the vent pipe of a hydrogen trailer failed, damaging the pipe and causing a hydrogen leak. The following fire damaged several other trailers. [Zalosh and Short, 1978]