HIAD Facility - Storage Medium: Gas


The incident occurred at a caustic soda electrolysis plant. A chlorine suction pump failed on a sodium hydroxide electrolysis unit. The arrest of the pump caused the stop of the electrolysis current.…

A fuel cells and hydrogen city bus was refuelling at a hydrogen refilling station. It had just terminated this operation and the engine was restarted, that an explosion occurred at the back of the…

Explosion in a chemical manufacturing plant for the pharmaceutical and cosmetics industries, classified as Seveso high level,The explosion occurred in the hydrogenation reactor, when opening two…
Explosion in a food products plant (Seveso classified) The event occurred in the settling cyclone of a hydrogenation reactor of a starch production unit. The process consisted in introducing the…
In a chemical plant, an explosion occurred on the primary reformer of an ammonia manufacturing unit.
A major leak (estimated between 1. 5 and 3 kg) of hydrogen from high-pressure storage, resulted in a detonation, from hydrogen a refuelling station. Causes were two untightened bolts securing the…
Huge explosion of liquid chlorine mixed with hydrogen took place on pulp and paper plant in Arkhangelsk. More than 50 tons of liquid chlorine exploded.
The incident occurred in a catalytic reforming unit. At 13:41, a leak occurred at the 90° elbow of a pressure pipe containing a mixture of hydrogen and naphtha. This pipe was located between the pre…
A tank "filled with low-pressure hydrogen" exploded at a food manufacturing plant, killing three workers. The accident occurred when the workers were welding inside the tank after clearing hydrogen…

an explosion occurred in a hydrogen storage tank at the hydrogen station of the oxygen plant of the energy centre. The 10 m3 hydrogen storage tank at the hydrogen station belonging to the oxygen…

The event started at the effluent pipe of one of the hydro-cracking reactors, which broke and released a mixture of hydrogen, light gases (methane, butane), light gasoline; heavy gasoline; gas oil.…
The balloon had a 3. 5m external diameter envelope made of anti-tear fabric (same techniques used in full sized balloons of the same company). The inner balloon was a meteorological balloon made of…
This incident occurred at the hydrogen production and storage unit of (probably) a power plant using hydrogen as a coolant of the turbine-generator system. Hydrogen was produced probably by water…
The accident happened during testing of a hydrogen tank at a company which manufactured valves and other hydrogen-storage components. A dull bang and a huge pressure wave was felt kilometres away.…
A researcher was conducting an experiment that involved sawdust being heated at pressure using hydrogen gas in an laboratory-scale autoclave. The gas leaked from the autoclave during the experiment…
A cylinder filled with hydrogen exploded. Hydrogen is used to blow up balloons
A serious chemical accident occurred at chemical industry producing olephins and phenols. The accident resulted in injuries to several workers and extensive damage to the plant, as well as minor…
A section of effluent piping ruptured on the hydrocracker reactor of a refinery. A mixture of light gases (methane, butane), light and heavy gasoline, gas oil and hydrogen was released from the pipe…

The incident occurred at a heat exchanger involving gas-product mixture. The source does not specify the process, with as main component a furnace, probably a hydrodesulphurisation reactor. Due to…

The loss of control of a reaction caused a fire in a pharmaceutical plant caused a reaction runaway and the rupture of a 6 m³ reactor. A cloud containing sodium borohydride and hydrogen was emitted.…